The SDi Solo C6 (SOLOC6) is a professional-grade, non-flammable carbon monoxide (CO) detector test aerosol designed for functional testing of compatible CO alarms, carbon monoxide detectors, and multi-criteria fire detection devices. Manufactured by SDi Fire, the Solo C6 delivers genuine carbon monoxide gas directly to a detector's sensing chamber to verify its response to an actual CO stimulus rather than relying solely on an electronic test button. Supplied in a 3-ounce aerosol can with an application nozzle, the silicone-free testing agent provides controlled delivery, rapid detector activation, and short reset times when used with approved equipment. It supports handheld application or use with compatible Solo 330 and Solo 332 aerosol dispensers for testing elevated detectors. The Solo C6 is UL Classified and endorsed for use with selected detector models, including compatible System Sensor carbon monoxide alarms. Designed for fire alarm technicians, inspection contractors, and facility maintenance personnel, the SDi SOLOC6 provides a practical solution for functional CO detector testing in commercial, institutional, industrial, and residential fire protection systems.
SDi Solo C6 Non-Flammable Carbon Monoxide Detector Test Aerosol, 3 oz
The SDi Solo C6 Carbon Monoxide Detector Tester provides a controlled source of genuine carbon monoxide gas for functional testing of compatible CO detection and life-safety equipment. Manufactured by SDi Fire, the SOLOC6 is a 3-ounce aerosol test agent designed to introduce a measurable CO stimulus into a detector's sensing chamber and confirm that its sensing element responds appropriately. Unlike electronic test buttons that may verify only internal circuitry or alarm signaling functions, application of a compatible CO test aerosol helps technicians evaluate the detector's response to carbon monoxide exposure. The product is intended for carbon monoxide alarms, system-connected CO detectors, and compatible multi-criteria smoke and carbon monoxide detectors that support manufacturer-approved functional gas testing procedures. The Solo C6 is particularly suitable for scheduled fire alarm inspections, preventative maintenance programs, system commissioning, and troubleshooting in commercial offices, apartment buildings, healthcare facilities, educational institutions, warehouses, and residential properties equipped with compatible CO detection systems.
The SDi SOLOC6 contains genuine carbon monoxide test gas in a non-flammable aerosol formulation developed for controlled functional detector testing. The manufacturer's safety data sheet identifies the aerosol as a pressurized mixture containing less than 0.3% carbon monoxide by mass, with a non-flammable classification under the applicable OSHA hazard communication test criteria. Its 3-ounce aerosol container provides a portable testing solution that can be transported between inspection locations and used without external electrical power, calibration instruments, or disposable electronic cartridges. The formulation is silicone-free and designed for fast detector activation and recovery when applied according to the detector manufacturer's instructions. SDi identifies Solo C6 as the first UL Classified carbon monoxide detector testing aerosol, with manufacturer endorsements for selected System Sensor and Interlogix CO detectors. Product performance depends on the detector's sensing technology, supported test mode, gas delivery method, and prescribed exposure interval. The pressurized container must be stored away from direct sunlight and temperatures exceeding 122 F (50 C), and the product must be handled in accordance with its published safety data sheet.
For fire alarm inspection and maintenance applications, the Solo C6 verifies the functional response of compatible carbon monoxide sensing elements by delivering a controlled quantity of real CO gas to the detector. SDi specifically identifies compatibility with selected System Sensor CO1224T, CO1224A, and CO1224R series detectors, as well as Interlogix SpaceAir 250 CO alarms, subject to the individual detector's testing instructions. Additional compatibility extends to approved multi-criteria fire detectors that combine carbon monoxide sensing with smoke detection and support external CO gas entry testing. The aerosol can be applied directly to the designated sensor opening when permitted or used with a Solo 330 or Solo 332 aerosol dispenser to provide controlled application around compatible ceiling-mounted detectors. For detectors installed at elevated locations, the dispenser can be mounted on a compatible Solo telescopic access pole, allowing technicians to conduct testing from floor level without positioning a ladder directly beneath every device. The Solo C6's non-flammable formulation, silicone-free composition, and detector manufacturer endorsements make it suitable for approved functional test procedures requiring a realistic CO sensing stimulus. It is not intended to replace calibrated gas concentration instruments or detector sensitivity testing methods where separate measurement or certification procedures are required.
Using the SDi Solo C6 detector test aerosol begins with verifying that the installed carbon monoxide detector supports aerosol gas entry testing and consulting the detector manufacturer's specified test procedure. Fire alarm technicians should notify the appropriate monitoring personnel, place connected systems into the authorized inspection or test mode, and follow the detector's instructions for activating its CO sensing test function when required. For direct application, the technician positions the supplied nozzle or straw near the designated CO sensing opening and applies the specified amount of test gas. For compatible ceiling-mounted devices, the Solo 330 or Solo 332 dispenser can be used to enclose the detector and deliver aerosol through its controlled activation mechanism. After application, technicians confirm the required detector response, observe the reset or recovery behavior, and restore the system to normal operation. The manufacturer emphasizes controlled application, appropriate ventilation, and compliance with the aerosol's safety and storage precautions. The canister should not be punctured, incinerated, or exposed to excessive heat, even after use. The related Solo A10 aerosol is designed for smoke detector testing, while Solo C6 is specifically formulated for carbon monoxide sensing applications. Combining genuine CO test gas, non-flammable aerosol delivery, UL Classification, and compatibility with professional Solo testing equipment, the SDi SOLOC6 provides a functional testing solution for fire alarm service companies, safety inspectors, and facility maintenance professionals responsible for carbon monoxide detection systems.