Schlage ND52 Keyed Privacy Lever Lock

  • MPN: ND52PD-RHO-626
  • JMAC ID: 203017597
$499.00
+ Free Shipping Free shipping on select options
JMAC_ID:
203017597
df_manual_boost:
1.00
More options

The Schlage ND52 is the keyed privacy function of the ND Series, Schlage heavy duty Grade 1 cylindrical lock. A key cylinder in the outside lever and a push button in the inside lever give privacy from inside with a key override from outside, on a deadlatch.

What makes it a privacy lock rather than an office lock is the release behavior: closing the door also unlocks it, so the room cannot be left locked with nobody in it. Pushing the button on the inside lever makes the outside lever inoperative. Turning the key outside, rotating the inside lever, or simply closing the door all retract the latch or release the button, unlocking the outside lever. The inside lever is always free for immediate egress.

Note that the key outside does not lock the door - it only unlocks. Locking is done from inside with the button, which is what you want on a room someone occupies and a keyholder may need to reach.

It takes conventional, FSIC, or SFIC cylinder formats, including less-cylinder options if you are supplying cores from an existing system. Conventional and FSIC default to the patented Everest 29 S123 keyway, and the lock can be keyed different, keyed alike, master keyed, or construction keyed. The ND Series margin over the standard carries through: 3,100 in-lb of abusive lever torque (2.6x BHMA), 1,600 lbs of offset lever pull (8x BHMA), and near zero droop and wobble after 16 million cycles (16x BHMA).

Features

  • Keyed privacy function - key cylinder outside, push button inside, deadlatch.
  • Anti lock-out - closing the door unlocks the outside lever.
  • Outside lever made inoperative by pushing the button on the inside lever.
  • Key outside does not lock - it unlocks and releases the button.
  • Rotating the inside lever also retracts the latch and releases the button.
  • Inside lever always free for immediate egress.
  • Conventional, FSIC, and SFIC cylinder formats, plus less-cylinder options for existing key systems.
  • Patented Everest 29 S123 keyway standard on conventional and FSIC cylinders.
  • Keyed different, keyed alike, master keyed, or construction keyed.
  • ANSI/BHMA Grade 1 certified to A156.2-2011, Series 4000.
  • Resists 3,100 in-lb of abusive lever torque, 2.6 times the BHMA requirement.
  • Restricts entry against 1,600 lbs of offset lever pull, 8 times BHMA.
  • Near zero droop and wobble after 16 million cycles, 16 times BHMA, with no set screws or O-rings.
  • Nine ADA compliant lever designs and nine finishes; inside lever can differ from outside.
  • Non-handed; UL Listed 3 hour fire rated and BAA compliant.

Specifications

Function

Schlage Function
ND52 keyed privacy lock
ANSI Function
None assigned
Trim
Lever with key cylinder outside; push button in the lever inside; deadlatch
Unlocked State
Latch retracted by either lever
Locking
Outside lever is made inoperative by pushing the button on the inside lever. The key outside does not lock
Unlocking
Key outside, or rotating the inside lever, retracts the latch and releases the button, unlocking the outside lever. Closing the door also unlocks, preventing lock-out
Egress
Inside lever always free for immediate egress

Cylinders and Keying

P6
Conventional 6-pin cylinder, Everest 29 S123 keyway
P
Conventional 6-pin cylinder keyed 5-pin, Classic C keyway
L
Less conventional cylinder, for supplying your own
R
FSIC 6-pin full size interchangeable core
J
Less FSIC core, for an existing full size interchangeable core system
H
Refundable construction SFIC core
B
Less SFIC core, for an existing small format interchangeable core system
Keying
Keyed different (standard), keyed alike, master keyed, or construction keyed
Default Keyway
Everest 29 S123 on conventional and FSIC cylinders. Master keyed systems default to Everest 29 S145
Pack Cylinders Loose
PCL available if cylinders should ship uninstalled

Performance

Abusive Lever Torque
3,100 in-lb, equivalent to over 690 lbs at the end of a 4-1/2 inch lever (2.6x BHMA)
Offset Lever Pull
1,600 lbs (8x BHMA)
Vertical Impact
100 impacts with no failure or indication of stress (20x BHMA)
Cycle Life
Near zero droop and wobble after 16 million cycles (16x BHMA)
Latch Preload
Latch retraction with 200 lb preload (4x BHMA)

Chassis and Trim

Chassis Material
Modular design of zinc and steel components, plated for corrosion protection
Handing
Non-handed
Door Thickness
Standard 1-5/8 to 2-1/8 inches. Optional 1-3/8 inches to 6 inches in EE, EO, EI, and ED configurations
Backset
Standard 2-3/4 inches, with 3-3/4 inch latches available and a 5 inch backset extension
Lever Designs
Athens (ATH), Boardwalk (BRK), Broadway (BRW), Latitude (LAT), Longitude (LON), Omega (OME), Rhodes (RHO), Sparta (SPA), Tubular (TLR), in pressure cast zinc plated to match the finish. The inside lever can be specified the same as outside or as a different design
Roses
Wrought brass or zinc, plated to match the finish. Rose diameter 3-7/16 inches
Finishes
605 bright brass (US3), 606 satin brass (US4), 612 satin bronze (US10), 613 oil rubbed bronze (US10B), 619 satin nickel (US15), 622 matte black (US19), 625 bright chrome (US26), 626 satin chrome (US26D), 643e aged bronze

Latch Options

13-247
Deadlatch, 2-3/4 inch backset, 1-1/8 x 2-1/4 inch square corner faceplate (standard)
13-248
Spring latch, 2-3/4 inch backset
14-028
Deadlatch, 3-3/4 inch backset, 1-1/8 x 2-1/4 inch square corner
14-010
Spring latch, 3-3/4 inch backset, 1-1/8 x 2-1/4 inch square corner, non-restoring
14-042
Anti-friction fire deadlatch, 3/4 inch throw, 2-3/4 inch backset, for pairs of doors
43-005
5 inch backset extension

Strike Options

10-025
ANSI strike, 1-1/4 x 4-7/8 inches, 1-3/16 inch lip (standard). Also available with the K510-066 dust box, or with a 1-3/8 or 1-1/2 inch lip
XQ07-351
10-025 strike with a 7/8 inch flat lip, or special lip lengths through 6 inches
10-013
T-strike with dust box, 1-1/8 x 2-3/4 inches, with a 1-1/8 or 1-1/2 inch lip
10-016
T-strike with deep dust box for the 3/4 inch fire latch, 1-1/8 x 2-3/4 inches

Certifications

ANSI/BHMA
A156.2-2011, Series 4000 Grade 1 cylindrical locks
Accessibility
Complies with ICC A117.1 Accessible and Usable Buildings and Facilities
Fire
UL 10C and CAN/ULC-S104. Three hour A label single fire door 4 ft by 10 ft. Pairs of doors three hour at 8 ft by 8 ft with the 3/4 inch latch option; pairs 90 minute at 8 ft by 10 ft with the 3/4 inch latch option
California Fire Code
Levers with a return to door of 1/2 inch or less comply: Rhodes, Sparta, Tubular, Omega, Longitude, and Boardwalk
Florida Building Code
Complies with Florida Building Code (ASTM E330, E1886, E1996) and Miami Dade (TAS 201, 202, 203) hurricane requirements
Federal
Meets FF-H-106C Series 161. BAA compliant on all functions
Warranty
10 year mechanical and 3 year electro-mechanical

Frequently Asked Questions

What does ND52 mean?
It is the Schlage function code for the keyed privacy lock. Key cylinder outside, push button inside, deadlatch, with a key override for staff.
How is this different from the ND50 entrance and office lock?
One behavior, and it is the reason both exist. On the ND52, closing the door unlocks the outside lever, so a room cannot be left locked when nobody is in it. On the ND50 the button stays pushed when the door closes, so the office remains locked after staff leave. Everything else about the two is the same.
Which one do I want?
Pick the ND52 for a room someone occupies and then leaves, such as a staff restroom, a changing room, or a private room that must not stay locked behind them. Pick the ND50 for an office that should stay secured after the last person leaves.
Can I lock the door with the key from outside?
No. On the ND52 the key outside does not lock. Locking is done with the push button on the inside lever. The key only unlocks, which is the point of a privacy function with an override.
Can people always get out?
Yes. The inside lever is always free for immediate egress, whether the button is pushed or not.
How is this different from the ND40 privacy lock?
The key. The ND40 is non-keyed, with a recessed emergency slot outside needing a key or screwdriver. The ND52 has a real key cylinder outside, so it works on a master key system and staff open it with their normal key.
Which cylinder option do I pick?
Match your existing key system. P6 is a conventional 6-pin cylinder on the patented Everest 29 S123 keyway, the Schlage default. P is a conventional cylinder on the open Classic C keyway. Pick R for a 6-pin FSIC core, H for a refundable construction SFIC core, or L, J, or B to receive the lock less cylinder or less core when supplying your own.
Can these be keyed to my existing keys?
Yes. Choose keyed alike to make a group open on one key, or master keyed to fold them into an existing system. Tell us your keyway and bitting or send a sample. Construction keying is also available.
Which latch do I need?
The standard 13-247 deadlatch on a 2-3/4 inch backset covers most doors. Use a 3-3/4 inch latch for deeper stiles, and the 14-042 anti-friction fire deadlatch with its 3/4 inch throw on pairs of doors, which is also what the pair-door fire listings require.
Does the lever choice matter for code?
It can. For the California Fire Code, levers with a return to door of 1/2 inch or less comply, which covers Rhodes, Sparta, Tubular, Omega, Longitude, and Boardwalk. Confirm the lever design against your local requirements.







For more information about the Schlage ND52-BASE, please contact us.
Live Chat