The System Sensor EOLR-1 is an epoxy-encapsulated, normally open SPST end-of-line supervision relay operating from 9-40 VDC with a maximum current draw of 20 mA. Designed for fire alarm power supervision, it monitors the presence of electrical power at the end of compatible four-wire smoke detector circuits and auxiliary power supply wiring. The relay features contacts rated at 3 amps at 30 VDC or 0.5 amps at 120 VAC for resistive loads, color-coded 8-inch minimum wire leads, and a compact housing measuring 0.91 x 1.65 x 1.22 inches.

System Sensor EOLR-1 End-of-Line Power Supervision Relay for Fire Alarm Systems

The System Sensor EOLR-1 is an epoxy-encapsulated end-of-line supervision relay designed to monitor electrical power integrity in fire alarm and life safety systems. Manufactured by System Sensor, a Honeywell brand, this compact relay provides a means of detecting power interruptions in compatible four-wire smoke detector circuits, remote fire alarm power supplies, and other supervised auxiliary power connections. The EOLR-1 incorporates a single-pole, single-throw (SPST), normally open relay contact that closes when the appropriate operating voltage is applied to its coil. When power is interrupted, the relay de-energizes and its contacts return to the normally open state, allowing a properly configured fire alarm control panel to recognize a loss of power as a trouble condition. This arrangement supports supervision of powered detection equipment in commercial buildings, institutional facilities, residential fire alarm systems, and other installations requiring monitored power distribution.

The EOLR-1 operates from a 9 to 40 VDC input voltage range, with a maximum operating current of 20 mA, making it suitable for typical 12V and 24V fire alarm power supervision applications. The manufacturer's installation documentation also specifies operation from 9 to 35 Vrms when supplied by an unfiltered full-wave rectified power source. Its relay provides normally open dry contacts rated for resistive loads up to 3 amps at 30 VDC or 0.5 amps at 120 VAC. The contacts are electrically separate from the relay's power input and can be connected to an appropriate supervised initiating or monitoring circuit. When voltage is present, the relay maintains the monitoring circuit in its intended normal condition; loss of voltage changes the contact state and allows the connected control panel to detect a circuit fault. The EOLR-1 does not independently generate an audible alarm or communicate with an addressable signaling line circuit. Instead, it operates as a conventional electromechanical supervision component within a properly designed fire alarm system.

The System Sensor EOLR-1 features a fully epoxy-potted enclosure measuring 0.91 inches high, 1.65 inches wide, and 1.22 inches deep (23 x 42 x 31 mm). Its encapsulated construction protects the internal relay components and provides a compact assembly suitable for mounting inside compatible electrical equipment or protective enclosures. The device uses four factory-attached, color-coded wire leads measuring at least 8 inches (203 mm) long. The red wire connects to positive operating power, the black wire connects to negative operating power, and the two violet wires provide the relay's common and normally open contact connections. This simplified wiring arrangement allows installers to connect the relay without a separate terminal block. The supplied installation accessories include four wire nuts, one piece of double-sided mounting tape, and one 1-1/4-inch mounting screw. The relay can be secured inside an equipment cabinet or attached to a suitable mounting surface using the included hardware. Its specified operating temperature range is -22 F to 140 F (-30 C to 60 C), with a relative humidity range of 10% to 93%, non-condensing.

The EOLR-1 is designed for end-of-line power supervision in compatible conventional fire alarm systems, particularly four-wire smoke detector installations requiring monitoring of detector operating power. When installed at the end of the supervised power wiring, the relay responds to the presence or absence of voltage, while the associated fire alarm control panel monitors the relay contact circuit for the appropriate normal or trouble condition. A properly selected end-of-line resistor and monitoring circuit arrangement may be required according to the control panel manufacturer's wiring instructions. Unlike a conventional end-of-line resistor, the EOLR-1 actively responds to the monitored power source through an energized relay coil, enabling the panel to distinguish a power failure from normal operating conditions when the supervision circuit is configured correctly. The device is also identified in System Sensor documentation as an accessory for compatible four-wire detection and fire alarm power supply applications. Its three-year limited manufacturer warranty applies from the date of manufacture, subject to the published warranty conditions. Combining wide-range low-voltage operation, SPST dry-contact switching, epoxy-encapsulated construction, and straightforward four-wire connections, the System Sensor EOLR-1 provides a compact solution for maintaining power supervision in professional fire alarm installations.



UPC: 783863024597
Also known as: BK-EOLR1

Technical Specifications:
  • Product Type: Relay
  • Additional Information: Operating temperature range:-22F to 140F (-30C to 60C)Humidity:10 to 93% RH non-condensingWire length:8?? min. (203 mm)Operating voltage:9 to 40 VDC ( 9 to 35 Vrms for unfiltered full wave rectified supplies)
  • Package Contents: EOLR1 End of Line Relay4 x Wire NutsPiece Of Double Sided Tape1 x 1 1/4?? Screw
  • Limited Warranty: 3 Year


For more information about the System Sensor EOLR1, please contact us.
  • Multipurpose field installations
  • Reliable and robust design
  • Multi-voltage operation
  • Easy and flexible installation
  • Terminal strip field wiring connections, mounting track, and hardware
  • LED viewing hole on top of the steel enclosure’s cover