Potter Amseco VSR-C-3 Waterflow Alarm Switch for 3" Copper Pipe for 3-inch Steel Pipe, with Retard, SPDT Contact(s)
VSR-C3 Potter / Amseco | JMAC Supply
 

Our Price: $281.13



Product Code: POTTER-AMSECO-VSRC3
Qty:

Description Product Resources Accessories
 

Potter Amseco VSR-C-3 Waterflow Alarm Switch for 3" Copper Pipe for 3-inch Steel Pipe, with Retard, SPDT Contact(s)


  • Also known as: VSRC3, PL-VSRC3

  • The Potter Electric VSR-C-3 is a vane-type waterflow switch for use on wet sprinkler systems. It is UL Listed for use on Type K, L, and M 3" copper pipe.

    The VSR-C-3 may also be used as a sectional waterflow detector on large systems.

    The VSR-C-3 contains two single poles, double throw, snap action switches, and an adjustable, instantly recycling pneumatic retard. The switches are actuated when a flow of 10 GPM (38 LPM) or more occurs downstream of the device. The flow condition must exist for a period of time necessary to overcome the selected retard period.

    For use with wet sprinkler systems, the Model VSR is a water flow switch of the vane type. For use on steel pipe, schedules 10 through 40, diameters 2" through 8," it is UL Listed and FM Approved (50 mm thru 200 mm). Sizes from 2" to 8" are LPC authorized (50 mm thru 200 mm).

    On large systems, the VSR can also be employed as a sectional waterflow detector. Two single poles, double throw, snap action switches and an instantaneously recycling pneumatic retard are included in the VSR. When a flow of 10 GPM (38 LPM) or more takes place downstream of the device, the switches are activated. To overcome the chosen retard period, the flow state must endure for the amount of time required.

    A general-purpose, die-cast enclosure houses the VSR switches and the retard device. Two tamper-resistant screws that need a unique key to remove hold the cover in place. As an extra, there is a field-installable cover tamper switch that can be used to signal unlawful cover removal.
    Features:
    • 3" pipe size for type K, L, and M copper pipe
    • NEMA 4 solid metal enclosure
    • Factory installed neoprene gasket
    • 0-90 second pneumatic retard
    • 175 psi system pressure rated
    • Non-corrosive saddle bushing
    • Two 1/2" KOs for dual voltage applications
    • 5-year warranty
    • Listings: UL, CSFM, and NYBSA


    Technical Specifications:

    • Service Pressure: 175 PSI (12,1 BAR) - UL
    • Flow Sensitivity Range for Signal: 4-10 GPM (15-38 LPM) - UL
    • Maximum Surge: 18 FPS (5.5 m/s)
    • Contact Ratings: Two sets of SPDT (Form C): 10.0 Amps at 125/250VAC, 2.0 Amps at 30VDC Resistive, 10 mAmps min. at 24VDC


    UPC: 785192015932

    How to Wire a Potter VSR Flow Switch to a Bell

    Average rating: 5.0, based on 2 reviews


    For more information about the Potter / Amseco VSR-C3, please contact us.

    Share your knowledge of this product with other customers... Be the first to write a review

    Browse for more products in the same category as this item:

    Potter / Amseco > Fire Sprinkler Monitoring > Flow Switches
    Potter / Amseco
    Potter / Amseco > Fire Sprinkler Monitoring