Potter Amseco VSR-AT-2 Auto-Test Waterflow Alarm Switch with Electronic Retard, 2" Pipe Size, Sprinkler Threaded Flow Switch With Plastic Threaded Union
-
MPN: VSR-AT 2
-
JMAC ID: 200414564
Videos Hide Videos Show Videos
The Potter Amseco VSR-AT-2 is an electronic vane type waterflow switch for use on wet sprinkler systems. It is UL Listed and FM Approved for use on steel pipe schedules 10 thru 40 size 2.
The VSR-AT-2 may also be used as a sectional waterflow detector on large systems. The VSR-AT-2 has two sets of alarm contacts and an adjustable instantly recycling electronic retard. The alarm contacts are actuated when a flow of 10 GPM (38 LPM) or more occurs downstream of the device. The flow condition must exist for a period of time necessary to overcome the selected retard time.
The VSR-AT-2 may be remotely tested without flowing water by using the optional auto test Control model ATC-1or ATC-4 or the use of addressable relays and monitor modules as part of a listed addressable fire alarm panel.
When the auto test feature is initiated, the VSR-AT-2 performs a self test to ensure compliance with UL requirements regarding waterflow detection and retard time. In addition, the auto test feature ensures the integrity of the paddle/trip stem assembly. A successful completion of the auto test will activate both sets of normally open contacts on the flow switch. If the auto test detects a problem with the trip stem/paddle assembly or if there is no water in the pipe, neither normally open contact will operate and the flow switch will indicate a trouble condition at the test switch and transmit a trouble signal to the fire alarm panel.
Enclosure
A general-purpose, die-cast enclosure houses the VSR switches and the retard device. Two tamper-resistant screws that need a unique key to remove hold the cover in place. As an extra, there is a field-installable cover tamper switch that can be used to signal unlawful cover removal. For this switch's installation instructions, refer to bulletin number 5401103.
UPC: 785192021575
Also known as: PL-VSRAT2, VSRAT2
For more information about the Potter / Amseco VSR-AT 2, please contact us.
The VSR-AT-2 may also be used as a sectional waterflow detector on large systems. The VSR-AT-2 has two sets of alarm contacts and an adjustable instantly recycling electronic retard. The alarm contacts are actuated when a flow of 10 GPM (38 LPM) or more occurs downstream of the device. The flow condition must exist for a period of time necessary to overcome the selected retard time.
The VSR-AT-2 may be remotely tested without flowing water by using the optional auto test Control model ATC-1or ATC-4 or the use of addressable relays and monitor modules as part of a listed addressable fire alarm panel.
When the auto test feature is initiated, the VSR-AT-2 performs a self test to ensure compliance with UL requirements regarding waterflow detection and retard time. In addition, the auto test feature ensures the integrity of the paddle/trip stem assembly. A successful completion of the auto test will activate both sets of normally open contacts on the flow switch. If the auto test detects a problem with the trip stem/paddle assembly or if there is no water in the pipe, neither normally open contact will operate and the flow switch will indicate a trouble condition at the test switch and transmit a trouble signal to the fire alarm panel.
Enclosure
A general-purpose, die-cast enclosure houses the VSR switches and the retard device. Two tamper-resistant screws that need a unique key to remove hold the cover in place. As an extra, there is a field-installable cover tamper switch that can be used to signal unlawful cover removal. For this switch's installation instructions, refer to bulletin number 5401103.
UPC: 785192021575
Also known as: PL-VSRAT2, VSRAT2
Technical Specifications:
|
For more information about the Potter / Amseco VSR-AT 2, please contact us.
- 2" nominal pipe size
- Electronic retard and integral failsafe trouble relay
- It monitors the integrity of the paddle/trip stem assembly
- Operates on 24 vdc, can be powered by the auxiliary power of most fire panels
- Self testing flowswitch can be operated by any addressable fire alarm panel or Potter AutoTest Control (ATC) switch