hold-up-wired

Hold-Up & Panic Devices

A hold-up device exists for one moment: an employee facing a robbery who needs to summon help without the offender knowing. Everything about the design follows from that. The alarm is silent at the premises, the switch is placed where a hand naturally rests under a counter or at a teller station, and activation is deliberate enough that it is not tripped by a knee or a broom handle.

Most are latching, meaning once operated they stay in alarm until reset with a key, so there is no question afterward about whether the signal was sent. Two-finger and dual-action designs require a specific motion to activate, which is what keeps accidental trips down in a busy retail environment. Because these are life-safety-adjacent and often required by the central station's protocol, they are typically wired on their own supervised zone using shielded cable on longer runs, and tested on a schedule agreed with the monitoring company. False activations carry real cost, so placement and staff training matter as much as the hardware.

See other hardwired devices under wired sensors and wired contacts, and exit control under request-to-exit sensors. Browse the full Honeywell Ademco / Resideo catalog. Contact our team for placement and zone setup.