System Sensor MOD2W Loop Test/Maintenance Module, 2-Wire

  • MPN: MOD2W
  • JMAC ID: 200417682
$105.00
Limited Stock
JMAC_ID:
200417682
df_manual_boost:
1.75
The MOD2W maximizes the benefits of the i 3 Series smoke detectors by enabling detector remote maintenance signaling and EZ Walk loop testing capabilities of models 2W-B and 2WT-B.

The MOD2W 2-wire loop test/maintenance module mounts to a 4-11/16 inch square back box for quick and easy installation. Terminal blocks with durable SEMS screws assure a reliable connection.

The MOD2W allows communication to 2-wire i3 detectors with any listed fire alarm control panel capable of utilizing this module. When these i3 detectors initiate a remote maintenance signal for required cleaning, both the MOD2W and the panel can provide a visual indication of the signal. The MOD2W module also features the EZ Walk loop test for 2-wire i3 detectors. With just the press of a button, this function verifies the entire initiating loop wiring.

The MOD2Ws green, red, and yellow LEDs provide status indication for the loop. These LEDs indicate loop communication status, maintenance alert, alarm, freeze trouble, EZ Walk test enabled, and wiring fault.

UPC: 783863045035
Also known as: BK-MOD2W

Technical Specifications:
  • Weight: 9.6 oz. 272 (g)
  • Standby Current: 60mA (max.), 38mA (12V In), 20mA (24V In)
  • Operating Voltage (VDC): Nom.: 12/24; Min.: 8.5 (2-wire); Max.: 35 VDC (power limited)
  • Operating Temperature Range: 0 50 C (32 122 F)
  • Operating Humidity Range: 5 - 95% RH
  • Maximum Ripple Voltage: 30% of applied power
  • Maximum Loop Wiring Resistance: 50 Ohms
  • Maximum Alarm Threshold: 9.2 Volts DC
  • Input Terminals: 14 to 22 AWG
  • Alarm Current: 185mA (max.)
  • Mounting: 4-11/16" square back box or inside a metal enclosure
  • Dimensions: Height: 6.04"; Width: 6.04"; Depth: 1.00"
  • Alarm and Maintenance Contact Rating: 100 mA @ 36 Volts DC, resistive, 25 ohms


For more information about the System Sensor MOD2W, please contact us.
  • Interprets the i3 detector remote maintenance signal
  • Provides visual indication and an output relay when a detector on the loop requires cleaning
  • Initiates the EZ Walk loop test
  • Provides Style D/Class A wiring on IDC loops
  • Allows up to twelve 2-Wire i3 detector models, 2W-B, 2WT-B and one 2WTR-B, to be used on any listed alarm control panel capable of utilizing this module