System Sensor 5604 Heat Detector, 194F Fixed Temp, Single-Circuit
-
MPN: 5604
-
JMAC ID: 200003842
The System Sensor 5604 is a conventional, single-circuit mechanical heat detector with a 194 F (90 C) fixed-temperature activation rating for fire protection applications where smoke detection may be unsuitable. Featuring normally open contacts, non-resettable thermal activation, and UL-listed spacing of 25 feet by 25 feet on 10-foot ceilings, it provides heat-activated alarm signaling to compatible fire alarm control panels. The detector includes a reversible mounting bracket, external activation indicator, and electrical contacts rated for AC and DC circuits.
System Sensor 5604 194 F Fixed-Temperature Mechanical Heat Detector
The System Sensor 5604 Mechanical Heat Detector provides fixed-temperature fire detection for commercial, industrial, and property protection applications where smoke detectors may be impractical due to environmental conditions. Manufactured by System Sensor, a Honeywell brand, the 5604 is part of the 5600 Series and features a single normally open detection circuit with a 194 F (90 C) alarm threshold. Its mechanical thermal sensing element activates when the surrounding temperature reaches the specified threshold, closing the electrical contacts to signal a connected fire alarm initiating device circuit. The detector is suitable for appropriately designed installations in mechanical rooms, utility areas, and other environments where elevated ambient temperatures or airborne particles can interfere with conventional smoke sensing. Unlike combination fixed-temperature and rate-of-rise models, the 5604 responds to its fixed-temperature threshold only and does not include a rate-of-rise sensing element.
The 5604 uses a non-resettable fusible-alloy thermal mechanism that holds a spring-loaded electrical contact in its normal position until the surrounding temperature reaches 194 F (90 C). When the alloy melts, the contact closes and the external heat collector drops from the detector, providing a visible indication that thermal activation has occurred. The detector's electrical contacts are rated for 3A at 6-125 VAC, 1A at 6-28 VDC, 0.3A at 125 VDC, and 0.1A at 250 VDC with resistive loads. Non-polarized screw terminals accommodate 14-22 AWG conductors for connection to compatible fire alarm circuits. The detector operates without a separate electronic power supply for its mechanical sensing function, with the monitored alarm circuit providing the electrical interface. Because the fixed-temperature element cannot be restored after activation, the complete detector must be replaced once its thermal mechanism operates.
The System Sensor 5604 is UL-listed for a maximum protected spacing of 25 feet by 25 feet on 10-foot ceilings, subject to installation conditions and applicable NFPA 72 spacing requirements. Its maximum specified installation temperature is 150 F (65.6 C), while the allowable operating humidity range is 5% to 95% relative humidity, non-condensing. The detector measures 4.57 inches (116 mm) in diameter by 1.69 inches (43 mm) high with its mounting bracket and weighs approximately 6 ounces (170 grams). A reversible bracket accommodates flush-mounted and surface-mounted installations using standard single-gang, 3-1/2-inch octagonal, or 4-inch octagonal electrical boxes. Installation is also supported on 4-inch square boxes equipped with a square-to-round plaster ring. The housing displays FX and 194 F/90 C identification markings, allowing installers and inspectors to distinguish the fixed-temperature model from rate-of-rise detectors and lower-temperature configurations.
The 5604 single-circuit fixed-temperature heat detector is designed for connection to compatible conventional fire alarm control panels and monitored initiating device circuits. Its mechanical contact arrangement supports fire alarm signaling without programmable addressing or onboard electronic processing. The 5604 differs from the System Sensor 5602, which combines 194 F fixed-temperature detection with a 15 F-per-minute rate-of-rise element, and the System Sensor 5624, which provides dual-circuit fixed-temperature operation at the same 194 F threshold. The lower-temperature 5603 model activates at 135 F (57 C). The 5600 Series is UL 521 listed and FM approved for applicable heat detection applications. The 5604 is intended primarily for property protection and should not be used as the sole fire detection device where smoke detection is required for life safety. Installation, inspection, and replacement must follow the manufacturer's instructions, applicable NFPA 72 requirements, and local authority having jurisdiction.
UPC: 783863022470
Also known as: BK-5604
Technical Specifications:
|
For more information about the System Sensor 5604, please contact us.
- Single-circuit
- Reversible mounting bracket
- Fixed temperature 135°F
- Easy-to-use terminal screws
- Single gang mounting
2 Reviews
-
SYSTEM-SENSOR-5604
-
SYSTEM-SENSOR-5604