The Exit Check 1511S series delayed egress EMLock incorporates an alternating 85 db tone and voice message with a digital countdown display and sign that provides clear and comprehensive instructions for persons without prior knowledge of door operation. This is especially significant for those who are blind or hearing impaired. The unit is for use with single doors equipped with Exit Sense Bars, surface vertical rod, concealed vertical rod, mortise and rim mount exit devices, mortise locksets and cylindrical locksets.

UPC: 712905212135
Also known as: SZ-1511SNDPV

Technical Specifications:
  • Dimensions: 11"L x 2-3/4"H x 2-5/8"D (279 x 70 x 67mm)
  • Finish: Aluminum
  • ATS Anti Tamper Sensor: (optional) SPDT Dry, 1 Amp @ 30VDC
  • BAS Magnetic Bond Status: (optional) SPDT Dry, 250 mA @ 30VDC
  • DPS Door Position Status: (optional) SPDT Dry, 250 mA @ 30VDC
  • Lock Secure Unlocked Output: SPDT Dry, 1 Amp @ 30VDC
  • Alarm Output: SPDT Dry, 1 Amp @ 30VDC
  • Holding Force Voltage: 830mA @ 12VDC, 450mA @ 24VDC
  • Holding Force: 1650lbs
  • Input Voltage: Dual Voltage Sensing 12/24 VDC 10%


For more information about the Security Door Controls 1511SNDPV, please contact us.
  • Aluminum finish
  • SDC Exit Check Delayed Egress Lock
  • Integrated
  • Surface Mount
  • Single
  • 1650lbs
  • Voice, Tone, and Digital Annunciator
  • California Building Code (OSHPD), NFPA 101, IBC & IFC Compliant
  • Built in reset push switch
  • Key reset, sustained bypass & timed bypass
  • UL, CSFM, MEA Listed
  • UBC & Califorinia compliant manual power up
  • Auotsensing 12/24VDC Voltage Input
  • Choice of 9 anodized & plated finishes
  • ANSI / BHMA Grade 1 Compliant
  • BHMA Certified Holding Force
  • Single Door Model
  • California Building Code, NFPA 101, IBC, IFC Compliant
  • Built-In Reset Push Switch
  • 1650lbs Holding Force
  • Emergency Release Input
  • Activation by door movement or exit bar
  • Locked & Egress Mode monitoring outputs
  • Adj. Timed bypass 1 - 30 sec.