Securitron XDT-12 Exit Delay Timer, 12VDC, for Delayed Egress System

  • MPN: XDT-12
  • JMAC ID: 200003658
$125.00
In Stock
  • Expedited Shipping Available Expedited Shipping Available
  • Need it Tomorrow?
    Need it Tomorrow?
    Select the NEED IT FAST shipping option at checkout and a member of our team will contact you promptly with any available Expedited Shipping options once we receive your order.
JMAC_ID:
200003658
df_manual_boost:
2.20

The Securitron XDT-12 is a 12VDC exit delay timer designed for delayed egress systems using fail-safe electric locks and compatible exit initiation devices. Featuring 15- or 30-second selectable release delays, adjustable 0-3 second nuisance delays, and three 5A SPDT relays, it provides configurable door release, alarm signaling, and lock monitoring. The board supports authorized entry, free egress, timed bypass, and BOCA 30-second relocking. Its modular design integrates with Securitron Magnalocks and access control equipment for commercial security applications.

Securitron XDT-12 12VDC Delayed Egress Exit Delay Timer Module

The Securitron XDT-12 Exit Delay Timer provides programmable delayed egress control for commercial access control systems using fail-safe electromagnetic locks and switch-equipped exit devices. Designed for healthcare facilities, retail stores, institutional buildings, and controlled-access environments, the timer allows authorized personnel to manage emergency exit functions while discouraging unauthorized door use. Operating on 12VDC power with a maximum current draw of 100mA, the XDT-12 coordinates electronic locking, audible alarm activation, and timed door release through a standalone circuit board. The device integrates with compatible Securitron Magnalocks, Touch Sense Bars, door position switches, and external control devices to create a modular delayed egress system. Its configurable operating modes accommodate facilities requiring different access restrictions throughout the day.

The XDT-12 provides selectable 15-second and 30-second exit release delays, with timing adjustments configured through a four-position DIP switch assembly. An independent nuisance delay function can be disabled or programmed for 1, 2, or 3 seconds to prevent accidental activation of the delayed egress sequence. The nuisance period is included within the total release delay rather than added to it. During the nuisance period, the timer activates a pulsing local alarm output; once the release sequence begins, the alarm changes to a continuous signal until the lock releases. The circuit board incorporates three 5A SPDT relays for lock control, local alarm activation, and remote alarm reporting. An optional 30-second BOCA relocking function provides timed door relocking following closure when configured for applicable building code requirements.

The Securitron XDT-12 supports bypass, free egress, lock status reporting, and authorized immediate release functions through dedicated control terminals. The bypass input allows external switches, key switches, or programmable time clocks to temporarily release the connected lock without activating the delayed exit alarm. A momentary bypass command provides a 5-second release period after the switch opens, supporting authorized entry or exit. Free egress mode permits immediate door release when the exit initiation device is activated while maintaining controlled entry from the opposite side. The optional lock status input monitors compatible door contacts or magnetic bond sensors and activates the remote alarm relay after a 5-second delay when a secured door is forced open or remains unsecured. External scheduling devices, including the Securitron DT-7 digital timer, can switch between operating modes to accommodate changing facility access requirements.

The XDT-12 is supplied as a circuit board without an integrated enclosure or alarm sounder, allowing installers to incorporate the module into compatible delayed egress control assemblies. The timer requires a filtered or regulated 12VDC power source, with an allowable voltage range of approximately 10.8-14.4VDC, and must be connected to a compatible fail-safe lock, exit initiation switch, reset device, and local audible alarm. The controller incorporates a low-voltage detection circuit that releases the connected lock when supply voltage falls to approximately 70% of nominal voltage, supporting fail-safe operation during electrical faults. The XDT Series is ANSI/UL 294 listed and California State Fire Marshal approved, with delayed egress installations subject to applicable NFPA 101, International Building Code, and local authority requirements. Alternative configurations include the BA-XDT-12 surface-mounted enclosure and FA-XDT-12 flush-mounted assembly, which incorporate audible signaling components. The XDT-12 is backed by Securitron's MagnaCare lifetime replacement, no-fault warranty.



UPC: 784607024781
Also known as: SN-XDT12, HES-XDT12, XDT12

Technical Specifications:
  • Voltage: 12 VDC


For more information about the Securitron XDT-12, please contact us.
  • External switches such as time clocks can put the XDT into different modes when delayed exit is not desired at all times
  • Nuisance delay and release times are digitally set using precise DIP switches
  • Three 5 Amp SPDT relays for interface capabilities
  • Meets all code requirements including the BOCA 30 second relock function
  • MagnaCare Lifetime Replacement No Fault Warranty