Home > Macurco > Toxic Gas Detectors >

Macurco TX-6-AM Ammonia Detector, Controller and Transducer, 12-24 VAC or 12-32 VDC, Dark Gray
TX-6-AM Macurco | JMAC Supply
 

Our Price: $687.73



Product Code: MACURCO-TX-6-AM
Qty:

Description Product Resources
 

Macurco TX-6-AM Ammonia Detector, Controller and Transducer, 12-24 VAC or 12-32 VDC, Dark Gray


  • Also known as: TX6AM, MA-TX6AM

  • The Marcurco TX-6-AM is a low voltage, dual relay, ammonia (NH3) detector, controller and transducer used to measure the concentration of NH3. The unit is equipped with an automatic exhaust fan control that helps reduce NH3 concentrations in industrial refrigerators, warehouses, and many other commercial applications.

    The TX-6-AM is a low level meter capable of displaying from 0-100 ppm of ammonia and has selectable 4-20 mA output, buzzer and digital display options.

    The TX-6-AM is also available in white.
    Features:
    • Dark gray housing
    • 12-24 VAC or 12-32 VDC input
    • 5A SPDT Fan control relay
    • 0.5A N.O. or N.C. Alarm Relay
    • Selectable Fan and Alarm Relay Actuation Settings
    • Digital Display (0-100ppm of NH3), Internal Buzzer
    • Coverage Area: 900 sq. ft.
    • 4-20mA current loop


    Technical Specifications:

    • Power: 3 W (max) from 12 to 24 VAC or 12 to 32 VDC
    • Current @ 24 VDC: 75 mA in alarm, 50 mA fan relay on and 23 mA stand by
    • Shipping Weight: 1 pound (0.45 kg)
    • Size: 4-1/2" x 4" x 2-1/8" (11.4 cm X 10.2 cm X 5.4 cm)
    • Color: Dark gray
    • Connections: plugs/terminals
    • Mounting box: (not included) 4x4 electric
    • Fan relay: 5 A, 240 VAC, pilot duty, SPDT, latching or non-latching
    • Fan relay actuation: selectable at OFF, 15, 20, 25 (default), 30, 35, 40, 45, 50, 55, 60, 65, 70, or 75 ppm NH3
    • Fan Delay Settings of 0, 1, 3 (default), 5 and 10 minutes
    • Fan Minimum Runtime settings are OFF (default), 3, 5, 10 or 15 minutes
    • Alarm relay: 0.5A 120 V, 60 VA
    • Alarm relay actuation: selectable N.O. default or N.C.
    • Alarm relay settings: OFF, 25, 30, 35, 40, 45, 50, 55, 60, 65, 70, 75 (default), 80, 85, 90, 95 or 100ppm NH3
    • Current Loop, 4-20 mA for 0-100 ppm NH3
    • Operating Environ: 0F to 125 F (-18C or above 52C).10 to 90% RH


    UPC: 783748831104

    Average rating: 5.0, based on 1 review


    For more information about the Macurco TX-6-AM, please contact us.

    Share your knowledge of this product with other customers... Be the first to write a review

    Browse for more products in the same category as this item:

    Macurco > Toxic Gas Detectors
    Macurco
    Fire & Life Safety > Gas Detectors
    Fire & Life Safety > Gas Detectors > Toxic Gas Detectors
    Fire & Life Safety