Macurco OX-6 0-25% Low-Voltage Oxygen Gas Detector

  • MPN: OX-6
  • JMAC ID: 200470833
$553.50
+ Free Shipping
Limited Stock
JMAC_ID:
200470833
df_manual_boost:
1.75

The Macurco OX-6 is a low-voltage oxygen (O2) detector, controller, and transducer designed to monitor oxygen concentrations in commercial and industrial environments. Featuring a 0-25% oxygen detection range, adjustable alarm thresholds, a 5A ventilation control relay, and a 0.5A alarm relay, it detects oxygen-deficient and oxygen-enriched conditions. The OX-6 operates on 12-24 VAC or 12-32 VDC and includes a digital concentration display, audible alarm, and selectable 4-20 mA output for building monitoring systems.

Macurco OX-6 Low-Voltage Oxygen Detector, Controller and Transducer

The Macurco OX-6 is a fixed oxygen monitoring device designed to detect changes in atmospheric oxygen concentration and activate connected ventilation or alarm equipment. Its electrochemical sensor measures oxygen levels from 0% to 25% by volume, supporting monitoring for oxygen depletion and enrichment in gas storage rooms, cryogenic facilities, laboratories, hospitals, and industrial environments. The detector functions as a standalone monitoring controller or connects to compatible centralized gas detection systems. A three-digit LED display provides oxygen concentration readings, while an integrated 85 dBA audible buzzer measured at 10 cm provides local alarm notification. Macurco specifies a coverage area of up to 1,257 square feet, subject to installation conditions and application requirements.

The OX-6 provides two independently configurable relay outputs for ventilation control and alarm notification. Its 5A SPDT fan relay, rated for 240 VAC pilot-duty operation, supports connected ventilation equipment, valves, and motor starters. The fan relay has a default low-oxygen activation threshold of 20.2% by volume, with adjustable settings and a preset high-oxygen threshold of 23.5%. A separate 0.5A alarm relay supports normally open or normally closed operation, with a default low-oxygen alarm threshold of 19.5%. Programmable fan delays, minimum ventilation run times, and selectable latching operation allow the controller to respond to changing oxygen levels. The detector also activates its fan and alarm relays when internal diagnostic faults are identified.

The Macurco OX-6 oxygen monitor supports 12-24 VAC or 12-32 VDC input power, with a maximum power consumption of 3 watts. At 24 VDC, current consumption is approximately 23 mA in standby, 50 mA with the fan relay activated, and 75 mA when both relays are activated. A selectable 4-20 mA analog output represents the measured 0-25% oxygen concentration for integration with compatible monitoring and control equipment, including the Macurco DVP-120 control panel family. The digital display and audible buzzer can be independently enabled or disabled. Its configurable outputs allow the OX-6 to operate ventilation equipment, activate external warning devices, or transmit oxygen measurements to a centralized monitoring system.

The OX-6 features a dark gray enclosure measuring 4.5 x 4 x 2.125 inches and installs over a standard 4 x 4-inch electrical box, which is sold separately. Its specified operating temperature range is 0 F to 125 F (-18 C to 52 C), with 10-90% relative humidity, non-condensing. The detector includes a field-replaceable electrochemical oxygen sensor with an expected service life of approximately two years. Calibration verification and sensor replacement are supported using compatible Macurco calibration accessories and oxygen test gas. The OX-6 is ETL listed to UL 61010-1 and CAN/CSA C22.2 No. 61010-1 for electrical equipment safety. Installation and calibration must follow manufacturer instructions, applicable safety standards, and the ventilation requirements of the monitored facility.



UPC: 783748834907
Also known as: OX6

Technical Specifications:
  • Operating Environment: 0°F to 125° F (-18°C to 52°C),10 to 90% RH non-condensing
  • Alarm relay settings: OFF, 18.5, 19, 19.5 (default), 20, 20.5 and high 23.5 % v/v (preset)
  • Alarm relay actuation: selectable N.O. default or N.C.
  • Alarm relay: 0.5A 120 V, 60 VA
  • Current Loop, 4-20 mA for 0-25% v/v O2
  • Fan Minimum Runtime settings are OFF (default), 3, 5, 10 or 15 minutes
  • Fan Delay Settings of 0, 1, 3 (default), 5 and 10 minutes
  • Fan relay actuation: selectable at OFF, 18, 18.1… , 20.2 (default), 20.3, 20.4 & 20.5% v/v and high 23.5 % v/v (preset)
  • Fan relay: 5 A, 240 VAC, pilot duty, SPDT, latching or non-latching
  • Mounting box: (not included) 4x4 electric
  • Connections: plugs/terminals
  • Color: Dark gray
  • Size: 4 1/2 x 4 x 2 1/8 in. (11.4 X 10.2 X 5.4 cm)
  • Shipping Weight: 1 pound (0.45 kg)
  • Current @ 24 VDC: 75 mA in alarm, 50 mA fan relay on and 23 mA stand by
  • Power: 3 W (max) from 12 to 24 VAC or 12 to 32 VDC


For more information about the Macurco OX-6, please contact us.
  • ETL Listed to UL 61010-1, CAN/CSA C22.2 No 61010-1
  • Dark gray housing
  • Fan relay actuation: selectable at 18, 18.1… , 20.2 (default), 20.3, 20.4 & 20.5% v/v and high 23.5 % v/v (preset)
  • Output: Fan relay, Alarm relay and 4-20mA current loop
  • Controls: Digital display (0-25% v/v), buzzer, fan delay, fan minimum runtime
  • Mounts on a standard 4” x 4” electrical box
  • 5 A SPDT fan relay controls valves, louvers or exhaust fans
  • 0.5 A N.O. or N.C alarm relay connects to warning devices or control panels
  • 4-20mA current loop - compatible with the Macurco DVP-120 Control Panel
  • Factory calibrated
  • Supervised system design: detector problem will cause the fan & alarm relay to activate
  • Optional calibration test kit allows the OX-6 to be field calibrated and tested

1 Review