Macurco OX-6-WHITE Oxygen Detector, Controller and Transducer, 12-24 VAC or 12-32 VDC, White Housing

  • MPN: OX-6 WHITE
  • JMAC ID: 200599932
$553.50
+ Free Shipping
JMAC_ID:
200599932
df_manual_boost:
1.50
The Macurco OX-6 is a low voltage, dual relay Oxygen (O2) detector, controller and transducer. The OX-6 has selectable 4-20 mA output, buzzer and digital display options. It is an electronic detection system used to measure the concentration of Oxygen and provide feedback and automatic exhaust fan control to help maintain appropriate Oxygen concentrations in commercial applications. The OX-6 is a low level meter capable of detecting from 0-25% by volume of Oxygen.


Also known as: OX6WHITE

Technical Specifications:
  • Operating Environment: 0°F to 125° F (-18°C to 52°C),10 to 90% RH non-condensing
  • Alarm relay settings: OFF, 18.5, 19, 19.5 (default), 20, 20.5 and high 23.5 % v/v (preset)
  • Alarm relay actuation: selectable N.O. default or N.C.
  • Alarm relay: 0.5A 120 V, 60 VA
  • Current Loop, 4-20 mA for 0-25% v/v O2
  • Fan Minimum Runtime settings are OFF (default), 3, 5, 10 or 15 minutes
  • Fan Delay Settings of 0, 1, 3 (default), 5 and 10 minutes
  • Fan relay actuation: selectable at OFF, 18, 18.1… , 20.2 (default), 20.3, 20.4 & 20.5% v/v and high 23.5 % v/v (preset)
  • Fan relay: 5 A, 240 VAC, pilot duty, SPDT, latching or non-latching
  • Mounting box: (not included) 4x4 electric
  • Connections: plugs/terminals
  • Color: White
  • Size: 4 1/2 x 4 x 2 1/8 in. (11.4 X 10.2 X 5.4 cm)
  • Shipping Weight: 1 pound (0.45 kg)
  • Current @ 24 VDC: 75 mA in alarm, 50 mA fan relay on and 23 mA stand by
  • Power: 3 W (max) from 12 to 24 VAC or 12 to 32 VDC


For more information about the Macurco OX-6 WHITE, please contact us.
  • Optional calibration test kit allows the OX-6 to be field calibrated and tested
  • Supervised system design: detector problem will cause the fan & alarm relay to activate
  • Factory calibrated
  • 4-20mA current loop - compatible with the Macurco DVP-120 Control Panel
  • 0.5 A N.O. or N.C alarm relay connects to warning devices or control panels
  • 5 A SPDT fan relay controls valves, louvers or exhaust fans
  • Mounts on a standard 4” x 4” electrical box
  • Controls: Digital display (0-25% v/v), buzzer, fan delay, fan minimum runtime
  • Output: Fan relay, Alarm relay and 4-20mA current loop
  • Fan relay actuation: selectable at 18, 18.1… , 20.2 (default), 20.3, 20.4 & 20.5% v/v and high 23.5 % v/v (preset)
  • White housing
  • ETL Listed to UL 61010-1, CAN/CSA C22.2 No 61010-1
Live Chat