GRI 2624 Water Sensor, Relay Contact, Normally Closed for a Closed Loop Circuit, 24 VDC
-
MPN: 2624
-
JMAC ID: 200104207
The George Risk Industries GRI 2624 is a commercial-grade, 24VDC water leak detection sensor designed to monitor conductive liquids and provide early warning of water accumulation through compatible security and environmental monitoring systems. Part of the GRI 2500/2600 Series Water Sensors, the 2624 features a normally closed relay output, automatic reset functionality, and moisture-sensitive contacts capable of detecting water depths as low as 1/16 inch (1.6 mm). Its closed-loop, fail-safe configuration opens the alarm circuit when conductive water is detected, external power is lost, or certain sensor failures occur. Operating from a 24VDC external power supply with approximately 12 mA current consumption, the sensor includes a built-in relay and a standard 6-foot jacketed four-conductor cable for connection to compatible alarm control panels, wireless transmitters, and annunciation equipment. The compact gray housing contains no mechanically moving water-detection components and automatically restores its normal relay condition when the sensing contacts dry. Manufactured in the USA and backed by a one-year limited warranty, the GRI 2624 is suitable for computer rooms, telecommunications facilities, water heater areas, laundry rooms, HVAC condensate pans, plumbing locations, and other environments requiring supervised water leak detection.
GRI 2624 24VDC Water Leak Sensor with Normally Closed Relay Contact
The George Risk Industries GRI 2624 Water Sensor provides continuous monitoring of conductive water and other compatible non-flammable liquids in residential, commercial, and institutional facilities. Manufactured by George Risk Industries as part of its 2500/2600 Series water detection family, the 2624 combines 24VDC operation, an integrated normally closed relay, and automatic moisture detection in a compact, surface-mounted sensing assembly. The device is designed to identify unwanted liquid accumulation near plumbing systems, water heaters, HVAC equipment, and other potential sources of water damage. Its moisture-sensitive contacts can respond to a layer of conductive water measuring approximately 1/16 inch (1.6 mm) deep when correctly positioned. Unlike standalone water alarms that rely on an internal sounder, the GRI 2624 provides an electrical relay output that can be connected to a compatible intrusion alarm panel, environmental monitoring system, or external annunciator. This arrangement allows facility operators to incorporate water leak detection into existing supervised alarm infrastructure. Typical applications include computer room subfloors, telephone equipment rooms, bathrooms, laundry facilities, utility closets, condensate drain pans, overflow areas, and locations adjacent to water storage tanks or piping.
The GRI 2624 incorporates solid-state moisture sensing circuitry and an internal relay contact that responds when a conductive liquid forms an electrical bridge across the sensor's exposed sensing elements. The manufacturer specifies a 24VDC operating voltage and approximately 12 mA operating current for the closed-loop water sensor family. Electrical connections are provided through a standard 6-foot (1.8-meter) jacketed cable containing four conductors. The red conductor connects to the positive DC supply, the black conductor connects to negative or ground, and the green and white conductors provide the relay contact connections for the monitored circuit. Manufacturer installation documentation specifies 30VDC maximum relay switching voltage, 500 mA maximum switching current, 100 milliohms contact resistance, and 250 mW maximum switching power. The sensor features a compact gray housing with approximate dimensions of 1.69 inches wide, 0.55 inch high, and 0.52 inch deep for the basic sensing body. Its electrical design does not require mechanical floats or moving sensing components, reducing potential wear associated with conventional mechanical liquid-level switches. GRI offers custom cable lengths for installations requiring alternative connection distances. The sensor is manufactured in the United States and carries a one-year warranty against defects in workmanship and materials.
For supervised environmental monitoring applications, the GRI 2624 provides normally closed relay operation intended for connection to a closed-loop alarm zone. During normal dry conditions, the externally powered sensor maintains its relay contact in the closed state, allowing the connected alarm system to recognize the normal circuit condition. When conductive water reaches the sensing contacts, the internal circuitry changes the relay state, opening the monitored circuit and allowing the associated control panel or transmitter to register an alarm. The relay also opens if operating power is lost, providing fail-safe alarm signaling for power interruptions and certain internal failure conditions. The manufacturer specifies that the relay can interface with compatible alarm panels, external transmitters, and annunciation devices, with end-of-line resistors installed in series with the relay wiring when required by the monitoring equipment. The automatic reset feature restores normal sensor operation after the conductive liquid is removed and the contacts dry, although an alarm condition may remain latched at the connected control panel until acknowledged or reset. The 2624 is the 24VDC version of the closed-loop GRI 2600 water sensor; related models include the 2600 for 12VDC operation and the 2605 for 5VDC operation. The GRI 2624T is a separate terminal-style configuration intended for remote sensing probes, while the standard 2624 uses its integrated sensing contacts. This distinction allows installers to select the appropriate sensor configuration according to the monitored location and wiring requirements.
Installation of the George Risk Industries 2624 water leak sensor involves positioning the sensing assembly in an area where leaking or overflowing water is likely to accumulate and connecting its four-conductor cable to a compatible 24VDC auxiliary power supply and normally closed alarm zone. The sensing contacts must remain accessible to the water being monitored, with their placement selected according to floor conditions, expected water flow, and the equipment or plumbing requiring protection. GRI identifies applications including computer room subfloors, telephone equipment spaces, water heater locations, bathrooms, laundry rooms, HVAC drip pans, drains, and overflow areas. The red conductor is connected to the positive 24VDC supply and the black conductor to the supply's negative terminal, while the green and white relay conductors connect to the selected closed-loop alarm circuit. Where the alarm panel requires end-of-line supervision, the appropriate resistor is installed in series with the relay circuit according to the panel manufacturer's wiring requirements. GRI recommends using a continuous external DC power supply rather than battery-only power because the sensor requires sustained power to maintain its normal relay condition. After installation, technicians verify proper operation by applying a damp sponge or paper towel to the sensing contacts and confirming that the monitored circuit reports an alarm. The device should also be tested for automatic restoration after the contacts dry. GRI recommends annual inspection and functional testing, with replacement if corrosion or physical damage is identified. Combining 24VDC power compatibility, 1/16-inch water detection capability, fail-safe closed-loop reporting, automatic reset, and integrated relay control, the GRI 2624 provides a practical monitoring solution for commercial and residential properties requiring early warning of water leaks and unwanted liquid accumulation.
UPC: 697625039685
Also known as: GI-2624
Technical Specifications:
|
For more information about the GRI 2624, please contact us.
- Available in gray only
- Will detect any conductive non-flammable liquid
- 6 foot jacketed lead standard
- Custom lead lengths available
- Automatic Reset
- Ideal anywhere water damage could occur
- 24 VDC