Stanley 17036 1200lb Delayed Egress Magnetic Lock, 12/24 VDC, UL294, Anodized Brushed Aluminum
-
MPN: 17036
-
JMAC ID: 200232216
The Stanley Healthcare 17036 is a 1,200 lb delayed-egress electromagnetic lock designed to secure emergency exits and perimeter doors while providing controlled, code-regulated egress. Operating on 12VDC or 24VDC, the lock features field-selectable 15- or 30-second release delays, an adjustable 0-3-second nuisance delay, and proximity-based door movement detection. Its integrated audible alarm, magnetic bond monitoring, microprocessor watchdog circuitry, and emergency fire alarm release interface support controlled-exit applications. The UL 294-listed unit features a brushed anodized aluminum housing and self-contained control electronics.
Stanley Healthcare 17036 1200 lb Delayed-Egress Electromagnetic Lock
The Stanley Healthcare 17036 Delayed-Egress Electromagnetic Lock provides integrated magnetic locking, controlled exit delay, and alarm notification for commercial, institutional, and healthcare facilities. Designed for secure perimeter doors and emergency exit openings, the lock delivers 1,200 pounds of nominal electromagnetic holding force while allowing occupants to initiate a controlled release sequence by applying pressure to the secured door. Its self-contained microprocessor-controlled electronics eliminate the need for a separate delayed-egress controller in supported installations. The lock works with compatible existing mechanical door hardware and features a brushed anodized aluminum housing with nickel-plated steel components. Applications include hospitals, assisted living facilities, healthcare environments, commercial properties, and other locations requiring coordinated security and emergency egress.
The Stanley 17036 incorporates field-selectable 15-second and 30-second delayed-egress cycles, with an adjustable 0-, 1-, 2-, or 3-second nuisance delay to help prevent inadvertent alarm activation. Its proximity-based activation system monitors movement between the door-mounted armature and the electromagnetic lock. When pressure causes the door to move approximately 3/16 inch, the system activates an internal piezoelectric audible alarm and begins the configured exit sequence. Once the nuisance interval has elapsed, the release countdown continues even if door pressure is removed. At the end of the programmed interval, the electromagnet releases and the audible alarm continues until the system is reset. The 30-second delay requires approval from the authority having jurisdiction, and the nuisance delay is included within the selected overall egress cycle.
The 17036 operates on 12VDC or 24VDC power with a +10%/-15% voltage tolerance. Maximum current consumption while locked is 525mA at 12VDC or 275mA at 24VDC, decreasing to approximately 25mA when unlocked. The lock incorporates a bond-sensing monitoring circuit that identifies insufficient magnetic engagement, low supply voltage, or armature misalignment, while microprocessor watchdog circuitry continuously checks the system's electronic operation. An integrated Form A or Form B selectable alarm output and a separate Form A status output, each rated at 0.5A at 30VDC, support connection to compatible remote monitoring equipment. Dedicated dry-contact inputs accommodate fire alarm release, remote lock control, and egress activation. The fail-safe locking mechanism immediately releases upon power loss or the required fire alarm signal, providing emergency unlocking independent of the programmed exit-delay interval.
The Stanley 17036 features a compact electromagnetic lock body measuring approximately 10-1/2 inches long, 2-3/8 inches deep, and 1-5/8 inches high, with an armature plate measuring approximately 7-1/4 x 2-3/8 x 5/8 inches. The manufacturer identifies an approximate shipping weight of 11 pounds and an operating temperature range of 32 F to 130 F (0 C to 55 C), with 0-95% non-condensing relative humidity. Installation uses the supplied mounting plates, spacer plates, armature hardware, and alignment components to accommodate suitable door and frame arrangements. The lock is not recommended for all-glass doors and requires sufficient solid wood or metal material for secure armature mounting. The manufacturer's documented package also includes a 12VDC plug-in power supply, installation template, and emergency exit instruction label. A compatible UL 294-listed Class 2 power supply is required for installations intended to maintain the applicable UL listing.
The Stanley Healthcare 17036 is UL 294 listed for special locking arrangements and is designed for delayed-egress applications governed by NFPA 101 Life Safety Code and applicable building regulations. The integrated alarm and lock monitoring functions help facilities manage controlled exit doors while preserving emergency release capability when correctly installed. Following a loss and restoration of power, the lock's default configuration requires manual activation of the Power Restore switch before normal locking resumes, with alternative operation available through approved configuration settings. Remote bypass and reset functions can be integrated with compatible keyswitches, keypads, and monitoring devices. Manufacturer instructions call for weekly operational testing, verification of fire alarm release, and inspection following electrical disturbances or changes to the door assembly. Combining 1,200 lb holding force, adjustable exit timing, self-contained monitoring electronics, and fail-safe emergency release, the Stanley 17036 provides a complete delayed-egress locking component for professionally designed access control and life safety installations.
UPC: 840948100031
Also known as: IS-17036
Technical Specifications:
|
For more information about the Stanley 17036, please contact us.
1 Review
-
STANLEY-17036