SDC 1511SNAKV Exit Check Delayed Egress Lock, Single
-
MPN: 1511SNAKV
-
JMAC ID: 200014753
The SDC 1511SNAKV ExitCheck is a single-door delayed egress electromagnetic lock providing 1,650 lbs of holding force and a selectable 15- or 30-second exit delay. Designed for NFPA 101 delayed egress applications, it combines an integrated three-position keyswitch, digital countdown display, verbal instructions, and audible alarm. The lock operates on auto-sensing 12/24 VDC power and features emergency release inputs, adjustable activation settings, and a 628 dull aluminum finish.
SDC 1511SNAKV ExitCheck 1,650 lb Delayed Egress Magnetic Lock with Keyswitch
The SDC 1511SNAKV ExitCheck delayed egress electromagnetic lock combines a 1,650 lb holding-force magnetic lock with an integrated alarm, verbal annunciator, and digital countdown display for controlled single-door egress applications. The NFPA 101 operating configuration provides a field-selectable 15- or 30-second exit delay, allowing authorized personnel to respond to attempted unauthorized departures before the door releases. Designed for healthcare facilities, assisted living centers, retail stores, transportation facilities, and secured commercial entrances, the 1511SNAKV supports perimeter security, loss prevention, and patient wandering prevention. Its integrated three-position keyswitch provides local alarm reset, manual power-up, and timed or sustained bypass functions.
The 1511SNAKV features auto-sensing 12/24 VDC input with a 10% voltage tolerance and draws approximately 820 mA at 12 VDC or 500 mA at 24 VDC. Its aluminum housing measures 11 inches long, 2-3/4 inches high, and 2-5/8 inches deep, while the armature measures 7-3/8 inches by 2-3/8 inches by 9/16 inch. The lock includes a field-selectable 1- or 2-second nuisance delay to reduce unintended alarm activation, along with an adjustable door movement sensor and selectable voice-message or alarm-only operation. Integrated SPDT lock-secure and alarm outputs are rated at 1A at 30 VDC resistive, providing status information to compatible access control and security monitoring equipment.
The SDC 1511SNAKV single-door ExitCheck system supports mortise and cylindrical locksets, rim exit devices, concealed vertical rod exit devices, and surface vertical rod exit devices. Delayed egress activation can occur through the built-in door movement sensor or compatible external switching devices, including monitored exit hardware and pressure-sensitive egress bars. When a delayed egress cycle begins, the lock activates its audible warning, displays the remaining release time, and provides verbal instructions until the selected delay expires. The system also supports remote reset, authorized access control bypass, anti-tailgate operation, and selectable relocking behavior following power restoration. An emergency release signal from a connected fire or life safety system overrides the delay and releases the electromagnetic lock immediately.
The SDC 1511SNAKV ExitCheck magnetic lock is configured for NFPA 101 Life Safety Code delayed egress operation and is identified in SDC documentation under UL 294 access control system listings and applicable fire-door assembly standards. Its integrated quick-mount assembly simplifies installation on compatible interior single-door openings, while the 628 dull aluminum finish provides a neutral appearance for commercial door hardware. Optional accessories include SDC angle brackets, filler plates, external annunciators, and compatible key control stations. Door Position Status (DPS), Bond Alert Status (BAS), and Anti-Tamper Status (ATS) monitoring are available as separately specified options rather than standard features of the 1511SNAKV. All installations require verification of applicable building codes, fire alarm integration, permitted egress delay, and approval by the local Authority Having Jurisdiction (AHJ).
UPC: 712905211831
Also known as: SZ-1511SNAKV
Technical Specifications:
|
For more information about the Security Door Controls 1511SNAKV, please contact us.
- UL, CSFM, MEA Listed
- NFPA 101, IBC, IFC Compliant
- Built-in Key Switch
- Single Door Model
- BHMA Certified Holding Force
- ANSI / BHMA Grade 1 Compliant
- Choice of 9 anodized & plated finishes
- Auotsensing 12/24VDC Voltage Input
- UBC & Califorinia compliant manual power up
- Key reset, sustained bypass & timed bypass
- Adj. Timed bypass 1 - 30 sec.
- Locked & Egress Mode monitoring outputs
- Activation by door movement or exit bar
- Emergency Release Input
- 1650lbs Holding Force
- UL, CSFM, MEA
2 Reviews
-
SDC-1511SNAKV
-
SDC-1511SNAKV