Potter Amseco UDACT-9100 Digital Alarm Communicator Transmitter / Dialer Module
-
MPN: UDACT-9100
-
JMAC ID: 200069300
The Potter Amseco UDACT-9100 Digital Alarm Communicator Transmitter/Dialer Module allows PFC-5000 or PFC-9000 Series Fire Alarm Control Panels to transmit Alarm, Supervisory, and Trouble information on two telephone lines to a monitoring facility.
The UDACT-9100 is powered by the host re alarm control panel and communicates with the re alarm control panel via an RS-485 data link. The unit can be congured for either DACT or UDACT operation.
The UDACT-9100 can be congured locally via the on-board keypad and the CFG-LCD Conguration Tool or with a UIMA programming tool and a computer with an available serial or USB port. In addition the unit can be remotely congured using a personal computer with a modem.
UPC: 785192014041
Also known as: PL-UDACT9100, UDACT9100
For more information about the Potter / Amseco UDACT-9100, please contact us.
The UDACT-9100 is powered by the host re alarm control panel and communicates with the re alarm control panel via an RS-485 data link. The unit can be congured for either DACT or UDACT operation.
The UDACT-9100 can be congured locally via the on-board keypad and the CFG-LCD Conguration Tool or with a UIMA programming tool and a computer with an available serial or USB port. In addition the unit can be remotely congured using a personal computer with a modem.
UPC: 785192014041
Also known as: PL-UDACT9100, UDACT9100
Technical Specifications:
|
For more information about the Potter / Amseco UDACT-9100, please contact us.
- Programmed to use the Ademco Contact ID and SIA-DCS reporting protocols
- Communicates with PFC-5000 or PFC-9000 Series fire alarm control panels via an RS-485 data link
- Can be configured for DACT or UDACT mode of operation
- DACT mode transmits a common Alarm, Supervisory, Waterflow and Trouble information
- UDACT mode transmits point-specific Alarm, Supervisory, Waterflow, and Trouble information
- UDACT-9100 has the ability of disconnecting the incoming and outgoing calls and capturing the line for transmission to the Digital Alarm Communicator Receiver (DACR)
- Onsite or remote programming
- Onsite configurable with the on-board keypad and the CFG-LCD Configuration Tool or using the UIMA Programming Tool and a computer with an available serial or USB port
- Remotely configurable via a Personal Computer with a modem (Configuration is passcode protected)
- Provides telephone line monitoring and reports status via LED indication on-board
- Provides event logs of 500 entries each to save events from local dialer or remote fire alarm panel
- Logs can be reviewed locally with the CFG-LCD Configuration Tool or remotely via modem
- Continuously supervises the status of each of two connected telephone lines at approximately one minute intervals
- Mounts in a dedicated location in the PFC-5000 or PFC-9000 Series main chassis