Norton Door Controls 5730-RF1 690
-
MPN: 5730-RF1 690
-
JMAC ID: 200346913
The 5700 Series design is based on ease and simplicity. This unit installs in minutes rather than hours and consists of three basic components: inverter, motor and Norton's 1601 closer body. Quiet and dependable, the 5700 meets the requirements of the Americans with Disability Act (A.D.A.) and ANSI/BHMA A156.4. Available push- or pull- side mounting, this unit is perfect for applications that don't require special features but demands reliability.
NORTON-5730-RF1-690, Stop (Push) Side of Door, w/Radio Frequency, Statuary Bronze finish (not shown)
Also known as: Y9-00030, 5730RF1690
For more information about the Norton Door Controls 5730-RF1 690, please contact us.
NORTON-5730-RF1-690, Stop (Push) Side of Door, w/Radio Frequency, Statuary Bronze finish (not shown)
Also known as: Y9-00030, 5730RF1690
For more information about the Norton Door Controls 5730-RF1 690, please contact us.
- 170° swing (trim permitting)
- Hold Open options; 0-30 seconds (5 seconds minimum required for ADA and ANSI/BHMA A156.19)
- Standard Duty Double Lever Arm
- Frame reveals 2-5/8" to 6-3/4" (67-171mm)
- Norton 1601/1601BF series door closer
- Non-Handed
- Application versatility and ease of adjustment; push or pull side mounting units available
- Unit Activation Options: wall switches, motion sensor, radio frequency device
- End-User On/Off Switch
- Simple instructions
- Ease of installation and setup
- Spring force provides the feel of a normal manual door closer; door can be opened manually if desired
- An auxiliary door stop is required for these applications
- Onboard power supply for accessories: 24VDC (1.1A)
- Operates as mechanical surface closer during close cycles, when door is opened manually or if power is turned off; quiet operation
- Motor Start Delay for Locking Hardware - 0-5 second delay to allow locking hardware to release first
- "Push and Close"; allows the operator to skip the hold open time when it is not necessary or required
- Adjustable door sensitivity
- Obstruction Detection: motor stops if door is obstructed during an opening; door closes under manual spring force (not to exceed 15lbf)
- Overload Safety Shut-Off - after two minutes of receiving a door activation signal, the inverter will time out and close the door; prevents motor/inverter damage