The HONEYWELL-4208SNF Remote Point Module (RPM) is a UL listed 8-zone expander that adds six class B and two class A expansions zones to any Vista Fire/Burglar control panel compatible with serial V-Plex polling loop devices.

UPC: 781410196582


Technical Specifications:
  • Sensor Loop Max Resistance: Loops A - F (Class 8); Up to 300 ohms of wire resistance + 10k EOLR; Loops G, H (Class A); Up to 150 ohms of wire resistance on each side
  • Loop Current: 0.52mA (normal), 1.3mA_ (shorted)
  • Loop Response: Slow: 400msec (all loops) Fast: 10msec (options for loops A and B)
  • Used as a Class A Converter – 12VDC Input Voltage: 12VDC nominal, 9.4 - 14VDC range, – Current: 22mA
  • 12VDC Input Voltage: 12V nominal: 9.4 - 14 VDC range – Current: 33mA when this input provides power to module (optional)
  • module; 0.6mA when 12VDC input provides power to module
  • Addressable V-Plex loop Voltage: 11v nominal; 8.7 - 14VDC range – Current 33.6mA when polling loop provides power to
  • Dimensions: 6-7/16" x 4-1/4" x 1-1/4" (163 mm x 108 mm x 32 mm)


For more information about the Honeywell Ademco 4208SNF, please contact us.
  • Provides cover tamper protection, which may be enabled or disabled via on-board DIP switches
  • Control panel’s response time to faults on the module’s Class A zones is equal to the response time of the control panel’s converted Class B zones plus one msec
  • Can be used on controls that support up to 250 zones
  • Provides up to six Class B supervised zones using external 10k EOL resistors and two Class A supervised zones using built-in 10k EOL resistors
  • Powered from addressable loop or optionally powered from an external DC power supply to reduce current draw from the addressable loop
  • Allows up to two Class B control panel zones to be converted into Class A zones
  • Each zone is identified by a unique serial number, which is assigned via on-board DIP switches
  • Detects faults an all zones with 400msec of occurrence. Two Class B zones can be optionally set for fast (10msec) response via on-board DIP switches
  • Must be powered from an external 12vdc power supply such as the 12v auxiliary power output on the control panel