Ditek D50-2401 50kA/Phase, 25 kA Mode Surge Protector, 240VAC Single Phase
-
MPN: D50-2401
-
JMAC ID: 200226024
The DITEK D50-2401 is a Type 1 industrial surge protective device designed to protect 240VAC single-phase electrical systems against transient voltage surges caused by lightning and electrical switching events. Featuring a 50,000-amp surge current rating per phase and per mode, 100,000-amp short-circuit current rating, and 10kA nominal discharge current rating, the device protects commercial electrical panels, disconnect switches, and HVAC equipment. Its NEMA 4X polycarbonate enclosure, diagnostic LED indicator, and individually fused protection components support surge protection in demanding indoor and outdoor environments.
DITEK D50-2401 240VAC Single-Phase Surge Protector, 50kA, NEMA 4X
The DITEK D50-2401 Industrial Surge Protective Device provides electrical surge protection for commercial facilities, industrial buildings, HVAC installations, and single-phase electrical distribution systems. Part of the DITEK ZEUS D50 Series, this UL 1449 Type 1 surge protector is specifically designed for 240VAC single-phase electrical services using a two-wire-plus-ground configuration. The device protects connected equipment against transient overvoltages associated with lightning-related surges, utility switching operations, and electrical disturbances. With a 50,000-amp surge current rating per phase, the D50-2401 is recommended for electrical panels rated up to 200 amps, including distribution panels, disconnect switches, and commercial HVAC electrical systems. Its parallel-connected design allows installation adjacent to the protected electrical panel without carrying the normal operating current of connected equipment. The compact enclosure incorporates individually fused surge suppression components that help isolate damaged protection elements during severe electrical events. Unlike the D50-120/2401, which protects 120/240VAC split-phase systems, the D50-2401 is intended for 240VAC single-phase services with the voltage configuration specified by the manufacturer.
The DITEK D50-2401 delivers 50,000 amps of surge current protection per phase and per mode, with a 100,000-amp short-circuit current rating (SCCR) and a 10kA nominal discharge current rating (In). Designed for 240VAC single-phase electrical systems, the device has manufacturer-listed maximum continuous operating voltage (MCOV) values of 320V/640V and provides voltage protection ratings of 1,200V line-to-neutral, 1,200V line-to-ground, and 2,000V neutral-to-ground. These ratings describe the device's electrical characteristics under standardized surge testing conditions. Operating at 50/60 Hz, the D50-2401 incorporates an LED diagnostic indicator that provides visual confirmation of system power and surge protection functionality. Its individually fused protection elements provide additional internal protection against electrical faults associated with surge suppression failure. The device features a NEMA Type 4X polycarbonate enclosure measuring 3.8 inches long x 3.7 inches wide x 2.62 inches high (97 x 94 x 67 mm) and weighs approximately 1.5 pounds (0.68 kg). Its operating temperature range extends from -31 F to 185 F (-35 C to 85 C), with a maximum relative humidity of 95% non-condensing, supporting installations exposed to varying environmental conditions.
The DITEK D50-2401 is UL 1449 5th Edition listed as a Type 1 surge protective device and certified to CSA C22.2 No. 269.1-17 for applicable North American electrical installations. Its Type 1 designation supports installation in approved electrical service and distribution configurations, subject to applicable electrical codes and manufacturer requirements. The NEMA 4X-rated enclosure provides protection against windblown dust, rain, splashing water, and corrosion-related environmental exposure, making the device suitable for appropriately installed indoor and outdoor applications. The integrated diagnostic LED allows maintenance personnel to visually check surge protection status without opening the enclosure, while its sealed construction protects the internal suppression components from environmental contaminants. Recommended applications include 240VAC single-phase electrical panels, commercial HVAC disconnect switches, industrial control equipment, and branch distribution systems where transient voltage protection is required. The D50-2401 is designed for parallel installation, allowing the protected electrical equipment to remain energized during normal operation. Its protective components are internally fused, and the device contains no user-serviceable parts. For applications requiring alternative electrical configurations, DITEK offers the D50-120/2401 for 120/240VAC split-phase systems and the D50-2403D for 240VAC three-phase Delta systems. A separate D50-2401FM configuration provides flush-mount installation for compatible panel arrangements.
Installation of the DITEK D50-2401 240VAC Surge Protector requires hardwired parallel connection to a compatible single-phase electrical panel using the supplied 3/4-inch NPT male conduit hub and 30-inch, 12 AWG wire leads. The manufacturer recommends a 20-amp single-pole circuit breaker, with the black phase conductor connected to the breaker load terminal, the white neutral conductor connected to the panel neutral bus, and the green grounding conductor connected to the ground bus. Before installation, a qualified electrician must verify that the measured electrical service voltage matches the D50-2401 rating and that the available fault current does not exceed the device's 100,000-amp SCCR. DITEK recommends mounting the surge protector as close as practical to the selected circuit breaker, with short, direct conductor routing to minimize additional voltage developed across the installation wiring during a surge event. The included 3/4-inch locknut secures the conduit fitting to the electrical panel, while integrated mounting feet provide an additional enclosure attachment method. After electrical connections are completed and power is restored, the diagnostic LED provides a visual indication of surge protector operation. The device must be replaced if its internal protection circuitry is no longer functional because the suppression components are not field-serviceable. The D50-2401 carries a 10-year limited manufacturer warranty and must be installed by a qualified electrical contractor according to DITEK installation instructions, applicable NFPA 70 National Electrical Code requirements, and local electrical regulations.
UPC: 782980517777
Also known as: DK-D502401, DTK-D502401, D502401
Technical Specifications:
|
For more information about the Ditek D50-2401, please contact us.
- Suitable for use on branch panels and small disconnects
- 50,000 Amp peak surge current capacity ensures long service life
- Available in 8 voltage configurations
- Diagnostic LED indicates system power and PSD function
- Complies with ANSI/IEEE C62.41 and C62.54 Category B and C3 standards
- Ten year limited warranty
- Compact size enables close mounting to the protected panel to minimize wire length and maximize performance
1 Review
-
DITEK-D50-2401