The Simplex 4098-9792 is a standard white TrueAlarm addressable smoke and heat sensor base designed for compatible Simplex fire alarm control panels using IDNet or MAPNET II communications. It supports 4098-9714 photoelectric smoke sensors and 4098-9733 heat sensors, providing detector mounting, two-wire power and data connections, and individual address identification. Featuring front-accessible DIP-switch addressing, an integral red status LED, and an anti-tamper locking mechanism, the base mounts to standard electrical boxes. The 4098-9792 is a base-only component; the compatible smoke or heat sensor head is sold separately.

Simplex 4098-9792 TrueAlarm Addressable Smoke and Heat Detector Base, White

The Simplex 4098-9792 TrueAlarm Sensor Base provides mounting, electrical connectivity, and addressable communication for compatible Simplex photoelectric smoke and heat detectors. Manufactured by Simplex, a Johnson Controls brand, this white standard sensor base accommodates the 4098-9714 photoelectric smoke sensor and 4098-9733 heat sensor, allowing installers to select the appropriate detection technology for the protected location. The base contains integral addressable electronics that identify the installed sensor to the fire alarm control panel and transmit detector information through the signaling line circuit. Designed for commercial and institutional fire protection systems, the 4098-9792 supports smoke and heat detection installations in offices, schools, healthcare facilities, hotels, warehouses, and other buildings equipped with compatible Simplex intelligent fire alarm systems.

The 4098-9792 communicates through Simplex IDNet or MAPNET II two-wire communications, receiving both operating power and data over the same circuit. Manufacturer specifications identify a 24-40 VDC communication voltage range and approximately 400 A typical current consumption for the standard TrueAlarm base configuration. Each base occupies one address on the compatible addressable circuit, with a front-accessible DIP switch located beneath the removable sensor head. This arrangement allows the address to remain associated with the installed location when a compatible detector head is replaced. The integral red status LED pulses during normal communication and illuminates steadily when the connected control panel identifies an alarm or applicable trouble condition. The base supports digital communication of sensor measurements for panel-based alarm processing, sensitivity monitoring, environmental compensation, and maintenance diagnostics, depending on the installed detector and control panel capabilities.

The Simplex 4098-9792 supports interchangeable TrueAlarm smoke and heat sensor heads, enabling technicians to replace or change compatible detection devices without replacing the mounting base or relocating its circuit address. When paired with the 4098-9714 photoelectric smoke sensor, the system can provide selectable smoke sensitivity, automatic environmental compensation, and detector status monitoring through the connected control panel. When fitted with the 4098-9733 heat sensor, supported systems provide configurable fixed-temperature and rate-of-rise detection functions. The base incorporates an anti-tamper locking feature that helps prevent unauthorized removal of the sensor head while allowing maintenance personnel to release it using the manufacturer's specified procedure. Unlike the 4098-9789 remote-indicator base or 4098-9791 supervised-relay base, the 4098-9792 is the standard configuration and does not provide additional relay or remote LED connection options.

The 4098-9792 mounts to standard 4-inch square or 4-inch octagonal electrical boxes with a minimum 1-1/2-inch depth, or a single-gang electrical box with a minimum 2-inch depth. Its screw terminals accommodate 14-18 AWG field wiring for incoming and outgoing IDNet or MAPNET II connections, with wiring arranged to maintain circuit supervision. The optional 4098-9832 adapter plate is required for specified surface-mounted or semi-flush 4-inch square box installations and surface-mounted 4-inch octagonal boxes. The base is designed for indoor use, with a manufacturer-listed operating temperature range of 32 F to 100 F (0 C to 38 C). Simplex TrueAlarm sensor bases are documented with applicable UL, ULC, CSFM, and FM approvals, subject to the installed sensor and complete system configuration. The 4098-9792 is a detector mounting and communication base, not a standalone smoke or heat detector, and requires a separately purchased compatible sensor head and supported Simplex fire alarm control panel. Installation must follow the manufacturer's instructions, panel compatibility documentation, and applicable NFPA 72 requirements.