Simplex 4098-9756 TrueAlarm Duct Sensor Housing with Relay

  • MPN: 4098-9756
  • JMAC ID: 202864523
$193.00
+ Free Shipping
  • Expedited Shipping Available Expedited Shipping Available
  • Need it Tomorrow?
    Need it Tomorrow?
    Select the NEED IT FAST shipping option at checkout and a member of our team will contact you promptly with any available Expedited Shipping options once we receive your order.
JMAC_ID:
202864523
df_manual_boost:
1.00
More options

The Simplex 4098-9756 is an addressable TrueAlarm photoelectric duct smoke sensor designed to detect smoke in HVAC air distribution systems and support fire alarm-controlled ventilation equipment. Featuring IDNet and MAPNET II communication, seven programmable sensitivity levels, and a supervised relay output supporting up to 15 remote relays, the unit includes a factory-installed 4098-9714 smoke sensor and one 4098-9843 relay. Its 24VDC relay power requirement, clear inspection cover, and UL 268A listing support commercial duct smoke detection applications.

Simplex 4098-9756 TrueAlarm Addressable Photoelectric Duct Smoke Sensor with Relay

The Simplex 4098-9756 TrueAlarm Addressable Duct Smoke Sensor provides intelligent smoke detection for commercial HVAC systems, industrial ventilation equipment, institutional facilities, and building fire alarm networks. Designed to monitor smoke within supply and return air ducts, the unit incorporates a factory-installed 4098-9714 TrueAlarm photoelectric smoke sensor, supervised multiple-relay control output, and clear polycarbonate inspection cover. The sensor communicates with compatible Simplex fire alarm control panels through IDNet or MAPNET II two-wire addressable communication, allowing the host panel to identify individual sensor conditions, monitor smoke levels, and initiate programmed responses. Unlike the basic 4098-9755 duct sensor housing, the 4098-9756 includes a supervised relay control interface capable of operating up to 15 compatible 4098-9843 remote relays. This configuration supports applications requiring smoke detection alongside fire alarm-controlled HVAC shutdown, damper operation, and auxiliary equipment control.

The 4098-9756 uses TrueAlarm analog photoelectric sensing technology with seven programmable sensitivity levels ranging from 0.2% to 3.7% smoke obscuration per foot. Sensor readings are transmitted digitally to the connected fire alarm control panel, which evaluates changing smoke conditions against stored reference values and applies environmental compensation for dust accumulation and sensor aging. The unit supports duct air velocities from 300 to 4,000 feet per minute (91 to 1,220 m/min) and operates within a temperature range of 32 F to 122 F (0 C to 50 C), with a UL-listed temperature range of 32 F to 100 F. Its separate relay control circuit requires 18-32VDC power, nominally 24VDC, with 3 mA standby current and 15 mA alarm current plus 15 mA for each connected relay. The included 4098-9843 relay provides a single Form C contact rated at 7A at 120VAC. Red and yellow diagnostic LEDs indicate sensor communication, alarm or trouble conditions, and supervised relay circuit faults.

The Simplex 4098-9756 integrates with compatible 4007ES, 4008, 4010, 4010ES, 4020, 4100, 4100ES, 4100E, and 4120 fire alarm control panels, subject to the supported IDNet or MAPNET II configuration. The controller manages programmable smoke sensitivity, sensor status, peak-value logging, automatic calibration checks, and relay activation commands. The supervised relay output supports up to 15 remote 4098-9843 relays over a maximum circuit distance of 500 feet (152 meters), enabling control of compatible HVAC fan shutdown circuits, smoke dampers, and auxiliary fire protection equipment. Each remote relay must be installed within 3 feet of the equipment being controlled, as specified by the manufacturer. The relay circuit requires a 4081-9008 end-of-line resistor harness rated at 10 k , 1/2 watt for supervision. Optional accessories include the 2098-9808 remote alarm indicator, 2098-9806 remote test station with keyswitch, and 4098-9845 weatherproof enclosure. The device is UL 268A listed for duct smoke detection applications, with additional approvals documented in Simplex product literature.

Installation of the Simplex 4098-9756 Addressable Duct Sensor supports rectangular ducts measuring at least 8 inches square and round ducts measuring at least 18 inches in diameter. The housing features a black ABS base, transparent polycarbonate cover, two 3/4-inch conduit entry provisions, and terminal connections accepting 12-18 AWG conductors. A factory-supplied exhaust tube works with an appropriately sized sampling tube, ordered separately, to direct duct airflow across the photoelectric sensing chamber. Compatible sampling tubes include 4098-9854, 4098-9855, 4098-9856, 4098-9857, and 4098-9858, selected according to duct dimensions. The housing includes magnetic test capability and external test ports for functional smoke testing and airflow measurements without removing the cover. Installers must verify an intake-to-exhaust pressure differential between 0.015 and 1.55 inches of water and select installation locations that provide representative, relatively nonturbulent airflow. The 4098-9756 requires a separate fused 24VDC fire alarm power supply for relay control and must be installed according to the manufacturer's instructions and applicable NFPA 72 and NFPA 90A requirements. Duct smoke detection is intended for air-handling system monitoring and control and does not replace required open-area smoke detection.








For more information about the Simplex 4098-9756, please contact us.