Gentex SHRR 917-0073-002 Multi-Criteria Smoke Alarm

  • MPN: SHRR (917-0073-002)
  • JMAC ID: 202790799
$99.00
+ Free Shipping
In Stock
  • Expedited Shipping Available Expedited Shipping Available
  • Need it Tomorrow?
    Need it Tomorrow?
    Select the NEED IT FAST shipping option at checkout and a member of our team will contact you promptly with any available Expedited Shipping options once we receive your order.
JMAC_ID:
202790799
df_manual_boost:
1.00

The Gentex SHRR (917-0073-002) is a 120 VAC multi-criteria photoelectric smoke alarm with an isolated, self-restoring 135 F heat sensor, rate-of-rise detection, and two Form A plus two Form C auxiliary relay contacts. Designed for residential and compatible institutional fire protection applications, it features an 85 dBA Temporal 3 audible alarm, 9V alkaline battery backup, 8-hour alarm memory, and 10-year end-of-life indicator. Its tandem interconnection capability, separate smoke and heat signaling contacts, and quick-disconnect wiring harness support coordinated notification and integration with compatible monitoring equipment.

Gentex SHRR 120V Photoelectric Smoke and Isolated Heat Alarm with Dual Relays

The Gentex SHRR (917-0073-002) is a hardwired multi-criteria photoelectric smoke and heat alarm with an isolated 135 F thermal sensor and auxiliary relay outputs, designed for single- and multiple-station fire warning applications. Part of the Gentex S Series, the SHRR combines photoelectric light-scattering smoke detection with a self-restoring fixed-temperature and rate-of-rise heat sensor to support detection of smoke and abnormal temperature conditions. The unit operates from 120 VAC, 60 Hz building power with a replaceable 9V alkaline backup battery, maintaining essential alarm operation during an interruption of primary electrical service. Its white housing and integrated piezoelectric sounder make it suitable for properly designed installations in homes, apartments, hotels, motels, dormitories, and other dwelling or institutional occupancies where compatible smoke alarm equipment is specified. The SHRR is distinguished from standard smoke-only alarms by its isolated heat-sensing circuit and separate relay connections for monitoring and auxiliary signaling.

The SHRR incorporates multi-criteria photoelectric smoke sensing with a nominal sensitivity of 2.5% obscuration and an isolated thermal sensor rated at 135 F (57 C). Its photoelectric detection chamber uses pulsed optical sensing to recognize airborne smoke particles, while an insect-resistant screen helps limit contamination and nuisance alarms. The isolated thermal assembly provides fixed-temperature and rate-of-rise heat detection, allowing compatible monitoring equipment to respond to thermal conditions independently of the smoke alarm's primary sensing function. During a smoke alarm condition, the built-in piezoelectric horn produces an ANSI Temporal 3 evacuation signal rated at 85 dBA at 10 feet, with a nominal horn frequency of 3100 Hz. The alarm incorporates a push-button self-test function and a separate functional testing feature, allowing occupants and maintenance personnel to verify the manufacturer's specified operation. An eight-hour alarm memory helps identify a device that has previously activated, while the red status LED pulses during normal operation and the green LED indicates the presence of AC power.

The Gentex SHRR features two Form A and two Form C auxiliary relay contacts for connecting compatible remote annunciation, supervisory, and signaling equipment. The separate switching arrangements provide alarm-related outputs associated with the smoke and isolated heat functions, enabling installers to distinguish the source of an activation in appropriately configured systems. Manufacturer literature identifies a 0.3-amp auxiliary relay rating, with the SHRR wiring documentation specifying resistive-load limits and individual connections for smoke alarm, smoke auxiliary, heat alarm, and supervision functions. The relays are designed to remain operational using backup battery power during an AC power failure, subject to proper battery condition and the manufacturer's wiring requirements. The device also supports Gentex tandem interconnection using a dedicated brown/yellow interconnect conductor, allowing compatible Gentex smoke, heat, and combination smoke/CO alarms to produce coordinated notification. When connected to compatible Gentex DUALINK-enabled equipment, the SHRR can participate in interconnected Temporal 3 smoke warnings and receive Temporal 4 notification signaling from compatible carbon monoxide alarms. The SHRR itself does not contain a carbon monoxide sensing element.

The Gentex SHRR operates from 120 VAC, 60 Hz power with a manufacturer-specified operating current of approximately 0.055 amp. A replaceable Duracell MN1604 9V alkaline battery provides secondary power, while a front-loading battery drawer simplifies replacement without requiring complete removal of the alarm from its mounting location. The alarm includes low-battery and missing-battery indication, along with a 10-year end-of-life notification function that identifies when the complete unit must be replaced. Its square-profile housing measures approximately 5.5 inches by 5.5 inches overall, with a 5.0-inch mounting base and a depth of 1.75 inches. The device supports mounting to compatible standard electrical junction boxes using the supplied mounting hardware and a quick-disconnect wiring harness. A protective dust cover helps prevent construction debris from entering the smoke sensing chamber before commissioning. The manufacturer specifies an ambient operating temperature range of 40 F to 100 F (4.4 C to 37.8 C), making the SHRR suitable for conditioned indoor environments rather than exposed outdoor locations.

The Gentex SHRR is designed for interconnected residential fire warning systems and compatible applications requiring separate smoke and heat alarm signaling contacts. Gentex identifies the S Series as listed to ANSI/UL 217, 9th Edition, for smoke alarm applications, with the SHRR incorporating an isolated thermal element for additional heat monitoring. The manufacturer's installation documentation supports tandem interconnection with selected Gentex S, SR, STRR, SHRR, H, C, CR, SC, SCR, SCRR, GN-503, CO1209, and S1209 Series appliances, subject to the specified interconnection limits and approved wiring arrangements. The SHRR includes its own model-specific wiring harness, which is not interchangeable with the harnesses supplied for other Gentex alarm configurations. Unlike the Gentex STRR, which incorporates an integral thermal sensor, the SHRR provides an isolated thermal circuit with separate signaling connections. It also differs from the standard Gentex S smoke-only alarm and the SR model with a single auxiliary relay set. The SHRR is backed by a one-year limited manufacturer warranty from the date of purchase, subject to Gentex's published terms. Combining photoelectric smoke sensing, isolated thermal detection, battery-backed operation, auxiliary relay signaling, and interconnected alarm support, the Gentex SHRR provides a specialized smoke and heat notification solution for compatible fire protection installations.



UPC: 700217047026


Technical Specifications:
  • Alarm Signal Patterns: Temporal 3 for smoke and heat.
  • Backup Power: 9V alkaline battery
  • Operating Voltage: 120VAC
  • Alarm Horn: 85 dBA at 10 feet
  • Relay Contacts: Two sets of Form A and Form C relays (0.3 amps)
  • Sensitivity: Nominal 2.5% obscuration
  • Thermal Sensor: Isolated 135°F self-restoring with rate-of-rise feature


For more information about the Gentex SHRR (917-0073-002), please contact us.
  • Dust Cover Included: Protects the sensor during installation from contamination.
  • Easy Installation: Quick-disconnect wiring harness and standard junction box compatibility simplify setup.
  • Operating Temperature Range: Maintains functionality in conditions from 40°F to 100°F.
  • Push-Button Self-Test: Allows users to easily verify functionality with a simple test.
  • Advanced Smoke Detection: Combines smoke detection with heat sensing for dual protection.
  • Interconnectivity: Compatible with Gentex tandem-capable smoke alarms
  • 85 dBA Alarm Horn: Powerful sound alerts occupants effectively at 10 feet distance.
  • Dimensions: Compact design with a diameter of 5.5 inches and depth of 1.75 inches.
  • Alarm Memory: 8-hour alarm memory assists in identifying alarm events.
  • Thermal Sensor: Isolated 135°F activation with a rate-of-rise feature for early detection.
  • One-Year Warranty: Comes with a one-year warranty for peace of mind.
  • Relay Contacts: Two sets of relay contacts (Form A and Form C) aid in alarm signaling.
Live Chat