Gentex SCR (918-0032-002) SC Series Smoke / Carbon Monoxide Alarm Detector with Relay, 120VAC

  • MPN: SCR (918-0032-002)
  • JMAC ID: 202790806
$111.00
+ Free Shipping
In Stock
  • Expedited Shipping Available Expedited Shipping Available
  • Need it Tomorrow?
    Need it Tomorrow?
    Select the NEED IT FAST shipping option at checkout and a member of our team will contact you promptly with any available Expedited Shipping options once we receive your order.
JMAC_ID:
202790806
df_manual_boost:
1.00

The Gentex SCR (918-0032-002) is a 120VAC combination smoke and carbon monoxide alarm with Form A/Form C relay contacts designed for residential and commercial-residential fire and CO protection. Featuring multi-criteria photoelectric smoke detection, an electrochemical CO sensor, and a 9V alkaline battery backup, it provides continuous monitoring during normal power operation and outages. The UL 217 and UL 2034-listed alarm includes an 85 dBA horn, Temporal 3 smoke signaling, Temporal 4 CO signaling, and interconnection with compatible Gentex alarms.

Gentex SCR 918-0032-002 Combination Smoke and Carbon Monoxide Alarm with Relay

The Gentex SCR (918-0032-002) Combination Smoke and Carbon Monoxide Alarm integrates two essential life safety detection functions into a single hardwired alarm designed for homes, apartments, hotels, motels, and other residential occupancies. Part of the Gentex SC Series, the SCR combines multi-criteria photoelectric smoke sensing technology with an electrochemical carbon monoxide sensor to detect smoke associated with fire conditions and hazardous CO concentrations. The multi-criteria sensing design helps reduce unwanted alarms while maintaining reliable detection performance. Operating from a 120VAC, 60Hz primary power supply, the unit includes a replaceable 9V alkaline battery for backup operation during electrical outages, supporting continuous occupant warning when properly maintained.

The Gentex SCR incorporates an 85 dBA piezoelectric alarm horn rated at 10 feet, with a nominal frequency of 3,100 Hz and separate audible patterns for smoke and carbon monoxide emergencies. Smoke detection initiates the Temporal 3 evacuation signal, while carbon monoxide detection activates the Temporal 4 warning pattern, allowing occupants to distinguish between alarm conditions. The smoke sensing chamber has a nominal sensitivity of 2.5% obscuration and includes insect screening to help prevent contamination. Additional operating features include an 8-hour alarm memory, a 10-year end-of-life indicator, push-button self-test and functional test capabilities, and visual status indicators for normal operation and alarm conditions. The unit is listed to ANSI/UL 217, 9th Edition, and ANSI/UL 2034 for smoke and carbon monoxide alarm performance.

For installations requiring external alarm signaling, the Gentex SCR provides one set of Form A/Form C auxiliary relay contacts that can activate during smoke or carbon monoxide alarm events. These contacts support integration with compatible remote annunciation equipment and auxiliary control circuits, subject to the manufacturer's electrical ratings and wiring requirements. The programmable relay also operates during battery backup conditions, providing additional flexibility for interconnected alarm applications. Gentex DUALINK interconnection technology allows the SCR to communicate with compatible Gentex smoke, carbon monoxide, combination smoke/CO, and heat alarms. When interconnected devices detect smoke or carbon monoxide, the connected alarms generate the corresponding warning pattern. Smoke alarm conditions receive priority when smoke and CO are detected simultaneously.

The Gentex SCR 918-0032-002 features a compact, universal-mount enclosure measuring approximately 5.5 inches in diameter and 1.75 inches deep, suitable for installation on compatible standard electrical junction boxes. A quick-disconnect wiring harness simplifies installation and service, while the front-loading battery drawer provides convenient access for backup battery replacement. Additional features include a low or missing battery warning, self-restoring alarm operation, and a protective dust cover for installation. The alarm operates in ambient temperatures from 40 F to 100 F (4.4 C to 37.8 C) and is intended for indoor applications. Manufactured by Gentex Corporation, the SCR carries a one-year limited manufacturer warranty and provides a combination smoke and carbon monoxide detection solution with auxiliary relay functionality for residential fire and life safety installations.



UPC: 700217047149


Technical Specifications:
  • Voltage: 120 VAC, 60 Hz; 9 V alkaline battery backup.
  • Sensitivity: Nominal 2.5% obscuration.
  • Sound Level: 91 dBA evacuation horn.
  • Listings & Approvals: ANSI/UL 217 and ANSI/UL 2034 Listed.
  • Dimensions: Diameter 5.5″ × Depth 1.75″.


For more information about the Gentex SCR (918-0032-002), please contact us.
  • Design: Combination smoke and CO alarm with integrated relay for remote monitoring.
  • Operation: Photoelectric smoke and electrochemical CO sensors work independently for faster detection.
  • Relay Output: Single Form A/Form C relay contact for external system connection.
  • Alarm Pattern: Temporal 3 for smoke, Temporal 4 for carbon monoxide.
  • Indicator: LED status for power, alarm, and maintenance.
  • Mounting: Easy-mount base with tamper-resistant locking feature.
  • Application: Suitable for integration with fire/security systems in commercial or residential settings.