System Sensor 2WTA-B Photoelectric i3 Smoke Detector, 2-Wire, Thermal Sensor, Built-In Sounder

  • MPN: 2WTA-B
  • JMAC ID: 200003829
$71.57
In Stock
  • Expedited Shipping Available Expedited Shipping Available
  • Need it Tomorrow?
    Need it Tomorrow?
    Select the NEED IT FAST shipping option at checkout and a member of our team will contact you promptly with any available Expedited Shipping options once we receive your order.
JMAC_ID:
200003829
df_manual_boost:
1.75
Please Note: In order to keep our prices low, we have a minimum order requirement of $99

The System Sensor 2WTA-B is an i3 Series two-wire photoelectric smoke detector with an integrated 135 F (57.2 C) fixed-temperature heat sensor and 85 dBA audible sounder. Designed for compatible conventional fire alarm control panels, it combines smoke detection, thermal detection, and local audible notification in a single device. Operating at 12/24 VDC nominal, the detector features automatic drift compensation, dual-color status LEDs, freeze trouble monitoring, and a plug-in mounting base for commercial fire alarm installations.

System Sensor 2WTA-B i3 Series 2-Wire Photoelectric Smoke and Heat Detector with 85 dBA Sounder

The System Sensor 2WTA-B i3 Series Smoke Detector combines photoelectric smoke sensing, fixed-temperature heat detection, and audible alarm notification for conventional fire alarm systems in offices, schools, healthcare facilities, apartment buildings, and commercial properties. Its photoelectric sensing chamber detects airborne smoke particles, while the integrated 135 F (57.2 C) thermal sensor provides an additional method of detecting fire conditions. A built-in 85 dBA piezoelectric sounder produces an ANSI S3.41 temporal-three alarm pattern when activated. The two-wire configuration connects to compatible UL-listed conventional fire alarm control panels, providing detection and local audible notification without requiring a separate sounder appliance at the detector location.

The 2WTA-B operates at a nominal 12/24 VDC with an allowable voltage range of 8.5-35 VDC and consumes a maximum average standby current of 50 A. Maximum alarm current is 130 mA under direct power, limited by the control panel, with different current requirements during reverse-polarity sounder activation. The detector has a nominal smoke sensitivity of 2.5% obscuration per foot and generates a freeze trouble indication when ambient temperature falls below 41 F (5 C). Its operating temperature range is 32 F to 100 F (0 C to 37.8 C), with 0-95% noncondensing relative humidity. The white detector measures 5.3 inches (134 mm) in diameter and 2.0 inches (51 mm) high, including its mounting base, and weighs approximately 7.1 ounces (200 g).

The System Sensor 2WTA-B incorporates advanced microprocessor-controlled smoke sensing with automatic drift compensation and smoothing algorithms that adjust for gradual contamination and help reduce nuisance alarms. Integrated red and green LED indicators provide visible status information for normal operation, alarm, out-of-sensitivity conditions, and freeze trouble. When connected to a compatible 2W-MOD2 loop test and maintenance module or i3 Ready control panel, the detector supports remote maintenance signaling and EZ Walk loop testing. The optional RRS-MOD reversing relay and synchronization module enables compatible i3 sounder detectors on the same circuit to activate together, synchronize their audible output, and respond to panel silence commands. These capabilities support coordinated fire alarm notification and streamlined inspection of supervised detection circuits.

The System Sensor 2WTA-B Photoelectric Smoke and Heat Detector features a plug-in detector head and included mounting base with Stop-Drop 'N Lock attachment for simplified installation and maintenance. The base accommodates single-gang, 3.5-inch and 4-inch octagonal electrical boxes, and 4-inch square boxes with plaster rings, along with direct ceiling mounting using appropriate anchors. SEMS screw terminals accept 14-22 AWG wiring, allowing installers to prewire the base before attaching the detector. A removable cover and sensing chamber facilitate inspection and cleaning, while the optional SENS-RDR sensitivity reader supports nonintrusive sensitivity measurements. The detector is UL 268 listed and FM approved for applicable fire protection signaling applications. Installation, detector spacing, testing, and maintenance must follow manufacturer instructions, NFPA 72, and local fire code requirements.



UPC: 783863019968
Also known as: BK-2WTAB, 2WTAB

Technical Specifications:
  • Dimensions: 2.0" (51mm) H x 5.3" (127mm) Dia.
  • Weight: 7.1 oz. (200 g)
  • Wiring Gauge: 14-22 AWG
  • Sensitivity: 2.5%/ft. nominal
  • Freeze Trouble: 41°F (5°C)
  • Operating Humidity Range: 0% to 95% RH, noncondensing
  • Operating Temperature Range: 32° to 100°F (0° to 37.8°C)
  • Standby Current: 50 µA max. avg., 100 µA peak
  • Alarm Current: 130mA max., limited by panel
  • Maximum Ripple Voltage: 30% of applied voltage (peak to peak)
  • Operating Voltage: 12/24 V non-polarized nominal, 8.5 min. to 35 max.
  • Sounder: 85 dBA
  • Heat Sensor: 135°F (57.2°C) fixed
  • Wiring: 2-wire
  • Detection: Photoelectric


For more information about the System Sensor 2WTA-B, please contact us.
  • 85 dB sounder
  • Dual-color LEDs
  • Simplified sensitivity measurement
  • Drift compensation and smoothing algorithms
  • Remote maintenance signaling
  • Removable cover and chamber
  • Stop-Drop ’N Lock attachment to the base
  • Flexible mounting options
  • In-line terminals
  • Plug-in design (base included)
  • Isolated thermal sensor
  • Form C relay