Magnasphere HSS-L2D-000 Dual Alarm Contact, Closed Loop
-
MPN: HSS-L2D-000
-
JMAC ID: 200106899
The Magnasphere HSS-L2D-000 is a UL 634 Level 2 dual-alarm high-security surface-mounted magnetic door contact designed for SCIFs, vaults, secure rooms, and critical intrusion detection systems. Featuring two independent normally closed alarm circuits, magnetic defeat detection, and a separate removal-tamper circuit, it provides monitored door position sensing with enhanced resistance to tampering. The sensor includes a silver-gray anodized aluminum housing, 36-inch stainless steel armored cable, and color-coded 22 AWG conductors. It supports a maximum 3/16-inch operating gap, with a recommended 1/8-inch gap for high-security installations, and contains no factory-installed EOL resistors.
Magnasphere HSS-L2D-000 UL 634 Level 2 Dual-Alarm High-Security Door Contact
The Magnasphere HSS-L2D-000 High-Security Magnetic Door Contact is a surface-mounted intrusion detection sensor engineered for facilities requiring advanced protection against unauthorized door opening, magnetic defeat attempts, and physical tampering. Part of the Magnasphere HSS Level 2 Series, the HSS-L2D-000 provides two independent closed-loop alarm contacts and a dedicated tamper circuit for integration with compatible high-security intrusion detection and access control systems. The device meets UL 634 Level 2 high-security requirements and is designed for applications involving Sensitive Compartmented Information Facilities (SCIFs), government buildings, military installations, financial institutions, secure data centers, safes, and vaults. Its patented magnetic switch technology provides an alternative to conventional reed-based magnetic contacts in installations requiring resistance to sophisticated sensor defeat methods.
The HSS-L2D-000 incorporates two independent normally closed alarm circuits that monitor the position of a protected door using Magnasphere's patented magnetic sensing technology. Each alarm circuit operates in the closed-loop condition when the supplied magnet is properly aligned with the sensor and changes state when the magnet moves outside its operating range. The device also features a separate closed-loop tamper circuit with magnetic defeat and pry/removal monitoring. The first alarm circuit uses white and black conductors, while the second uses orange and purple conductors. The tamper circuit uses green, yellow, and blue conductors to distinguish supervised common, magnetic tamper, and magnet/pry tamper connections. The standard HSS-L2D-000 contains no embedded end-of-line (EOL) resistors, allowing installers to configure supervision according to the connected alarm panel's requirements. Maximum electrical ratings are 30VDC, 250mA resistive current, and 0.25W switching power.
Designed for high-security door monitoring and resistance to deliberate magnetic manipulation, the Magnasphere HSS-L2D-000 incorporates sensing technology that responds to attempts to defeat the contact using external or internally positioned magnets. The independent magnetic tamper circuitry detects abnormal magnetic conditions, while the removal-tamper mechanism monitors attempts to separate the sensor from its mounting surface. A concealed tamper magnet is installed over a protected mounting screw and secured beneath a locking cap. Removing the protective hardware disturbs the tamper circuit before the sensor can be detached, providing an electrical indication of potential unauthorized manipulation. The device's hermetically sealed switching elements and fully encapsulated internal components provide resistance to environmental exposure and contact welding associated with electrical surges. Its dual alarm configuration supports applications requiring two separate door position inputs, independent alarm processing, or additional detection circuit redundancy.
The Magnasphere HSS-L2D-000 supports surface-mounted installation on compatible swinging and sliding security doors using the manufacturer's cross-hole mounting arrangement. The sensor can be integrated with appropriately configured intrusion alarm panels that accept contact inputs, with the two alarm circuits connected separately or according to the approved system design. The manufacturer specifies a maximum operating gap of 3/16 inch (4.78 mm) and recommends a 1/8-inch (3.18 mm) actuation gap for maximum resistance to internal magnetic defeat. Proper magnet orientation, door alignment, and tamper circuit termination are essential to reliable operation. The manufacturer's architectural specifications identify the HSS Level 2 Series for applications associated with ICS 705 high-security facility requirements, with suitability for intrinsically safe simple-apparatus installations when used with the required approved interface equipment.
The Magnasphere HSS-L2D-000 features a silver-gray anodized aluminum housing measuring 4.25 inches long, 1 inch wide, and 1.5 inches high. The standard assembly includes a 36-inch stainless steel armored cable containing seven color-coded 22 AWG conductors, with custom cable lengths available through the manufacturer. Its encapsulated construction supports indoor and outdoor installations across an operating temperature range of -40 F to 176 F (-40 C to 80 C). The HSS-L2D-000 is designed for use with compatible UL-listed intrusion detection controllers and carries the manufacturer's three-year limited warranty. Unlike resistor-equipped HSS-L2D variants, the -000 configuration provides unmodified alarm and tamper contact circuits for external supervision. Its combination of dual alarm outputs, UL 634 Level 2 security, magnetic defeat resistance, armored cabling, and independent removal-tamper monitoring makes it suitable for demanding government, institutional, industrial, and critical infrastructure security applications.
Also known as: MR-HSSL2D000, HSSL2D000
Technical Specifications:
|
For more information about the MAGNASPHERE HSS-L2D-000, please contact us.
2 Reviews
-
MAGNASPHERE-HSS-L2D-000
-
MAGNASPHERE-HSS-L2D-000