Ditek DTK-2LVLPF Fire Alarm Surge Protector, 1-2 Pairs, #22-10 Wire Gauge, 24V
-
MPN: DTK-2LVLPF
-
JMAC ID: 200016243
The DITEK DTK-2LVLPF is a 24VDC fire alarm signaling line circuit (SLC) surge protector designed to protect sensitive fire alarm control panels against induced electrical surges and transient overvoltages. Supporting up to 2 pairs of SLC wiring, a 5,000A surge current rating, and 5A maximum continuous current, it provides differential-mode and common-mode protection. The device features 39V clamping voltage, screw terminal connections, and UL 497B certification for low-voltage signaling circuit protection.
DITEK DTK-2LVLPF 24V Fire Alarm SLC Surge Protector
The DITEK DTK-2LVLPF Fire Alarm SLC Surge Protector provides transient voltage protection for 24V signaling line circuits connected to fire alarm control panels. Designed to protect sensitive electronic control boards from induced electrical surges, the device supports up to 2 pairs of SLC wiring used in commercial fire detection and emergency signaling systems. Its compact, hardwired construction makes it suitable for installation near fire alarm control equipment, where incoming field wiring can introduce damaging voltage transients. The DTK-2LVLPF also supports compatible 4-20mA current loop applications requiring low-voltage surge suppression.
The DTK-2LVLPF provides a 24VDC service voltage, 33V maximum continuous operating voltage (MCOV), and 39V clamping voltage to limit transient overvoltages before they reach connected equipment. Its protection circuitry supports differential-mode (line-to-line) and common-mode (line-to-ground) surge suppression, with a rated surge current capacity of 5,000 amperes and a maximum continuous current of 5 amperes. The device uses a series wiring connection with parallel surge protection functionality, allowing it to suppress transient voltages without introducing additional series resistance into the protected signaling circuit. These characteristics support protection of compatible fire alarm signaling loops while maintaining normal circuit operation.
Installation uses screw terminals accommodating 30-12 AWG conductors, with separate input and output connections for unprotected field wiring and protected equipment wiring. The DTK-2LVLPF measures 3.3 inches long, 1.55 inches wide, and 1.1 inches high (84 39 28 mm), weighs approximately 3.2 ounces (91 g), and features an ABS housing. The device supports mounting with the supplied double-sided tape or mounting screws, with an optional DITEK DTK-DRK DIN rail mounting kit available for compatible installations. Manufacturer instructions specify a minimum 3-foot wiring distance between the surge protector output and protected equipment, along with a dedicated grounding connection using at least 14 AWG wire.
The DITEK DTK-2LVLPF is designed for fire alarm signaling circuits in commercial, institutional, and industrial facilities requiring protection against electrical disturbances entering through connected field wiring. It operates within an ambient temperature range of -40 F to 158 F (-40 C to 70 C) and supports relative humidity up to 95% non-condensing. The surge protector is UL 497B certified, RoHS compliant, and backed by a 10-year limited warranty. Proper installation requires grounding in accordance with the manufacturer's instructions and applicable electrical codes, with the grounding resistance not exceeding 25 ohms and 5 ohms or less recommended. Circuit voltage, operating current, and compatibility with the fire alarm control panel must be verified before installation.
UPC: 782980507235
Also known as: DK-2LVLPF, DTK2LVLPF
Technical Specifications:
|
For more information about the Ditek DTK-2LVLPF, please contact us.
- Protects 1 or 2 pairs of SLC loops
- Series connection, parallel function adds no resistance to loop circuits
- Recommended for ‘legacy’ Fire Alarm Control Panels
2 Reviews
-
DITEK-DTK-2LVLPF
-
DITEK-DTK-2LVLPF