Knowledge Base:  

How do I install a Fortrezz Z-Wave wireless siren on my Lynx Touch L5100?


Last Updated: 12/02/2013
By

Follow these instructions to install the Fortrezz Z-wave wireless siren to the L5100:

(you will need the L5100 Z-wave Module)


1. Power down the L5100 Control Panel.
2. In the "Telephone Side" port, install the L5100 Z-Wave Module.
3. Power on the panel. Enter programming mode. Scroll down and press Z-wave. Click "Enabled-Installed Telephone Side," then click "Save."
4. Exit programming mode and return to the Home screen. Select "Automation," scroll down and select "Tools," then click "Include Devices."
5. Plug the FortrezZ into a nearby outlet, then quickly press and release the program switch on the back of the siren. The learned FortrezZ LCC Switch will appear on the display. Jot down the device number.
6. Press "back" twice and then select "Scenes" in the Automation screen.
7. Click "Add New Scene," then "Name," then "Sounder On." Click "Add Device," then "Switches," then select the proper device switch for your FortrezZ. Repeatedly press the "+" sign until "ON 100%" is displayed. Press Save.
8. Press "Back" twice, then select "Add New Scene." Choose "Name" and title the scene "Sounder Off". Select "Add Device," then "Switches." Choose the switch for your FortrezZ device. The switch should display "OFF 0%". Press "Save."
9. Return to the automation screen by pressing "Back" three times. Then select "Rules".
10. In an unused rule, choose "Edit," and name the rule "Sounder On."
11. In the "Type" box, click the section until "Scene" is displayed.
12. Now press the "scene" box (to the right of the name box, and select "Sounder On."
13. In the "action" box, select "Run Scene."
14. Choose an action that "Starts" the siren. "System Operation 1" and "Any Burg Alarm" is recommended. Click "Save" when done.
15. Choose another unused Rule and click "Edit". Designate this rule "Sounder Off."
16. Locate the "Type" box. Click it until "Scene" appears.
17. Press the "Scene" box that has appeared to the right of the "Name" box until "Sounder Off" appears.
18. Click the box labeled "Action" until "Run Scene" appears.
19. Choose the action that will stop the siren. "System Operation 1" and "Bell Timeout" are recommended. Then click "Save."
20. Back out to the Home Screen and the device is now installed. You can test the siren/strobe by triggering an alarm.


Similar Products:
FortrezZ SSA2 Z-Wave Siren w/ Red Strobe
FortrezZ MIMOLITEUS Z-wave Interface / Bridge Module


Was this article helpful?