Just like the lower Vista Panels, the Vista 128BPT is compatible with cellular alarm communicators like the GSMV4G.


To install the GSMV4G Cellular Communicator...

Shut off power to the Vista 128BPT by disconnecting the AC transformer and the back-up battery.  Now its time to connect terminals 3-6 on the GSMV4G to 6-9 ECP terminals on the Vista 128BPT using four-conductor wire.  


Connect:
GSMV4G's 3rd terminal to the Control Panel's 6th terminal using the red wire.
GSMV4G's 4th terminal to the Control Panel's 7th terminal using the black wire.
GSMV4G's 6th terminal to the Control Panel's 8th terminal using the yellow wire. 
GSMV4G's 5th terminal to the Control Panel's 9th terminal using the green wire.


Connect the battery back-up to the charging circuit of the GSMV4G.  Use two-conductor wire to connect the AC terminals on the GSMV4G to AC terminals 1 and 2 on the transformer.  Now mount the GSMV4G communicator to the wall and replace the plastic cover.  

Congratulations!  Your installation is now complete!