HES 1006 Series Electric Strike - ANSI Grade 1 Security
-
MPN: 1006CLB-630
-
JMAC ID: 203008443
- JMAC_ID:
- 203008443
- df_manual_boost:
- 1.50
- Popular Config 1:
- Satin Stainless Steel, Fail Secure, No Pack|HES-1006-630|1550:7442,1553:7457,1551:7449,1552:7452
- Popular Config 2:
- Satin Stainless Steel, Fail Secure, CLB Pack|HES-10620443|1550:7442,1553:7457,1551:7449,1552:7455
- Popular Config 3:
- Satin Stainless Steel, Fail Secure, CS Pack|HES-10620496|1550:7442,1553:7457,1551:7449,1552:7454
The HES 1006 Series is an ANSI/BHMA Grade 1 heavy-duty electric strike designed for commercial access control applications using cylindrical and mortise locksets, including configurations with a 1-inch deadbolt. Constructed from stainless steel with a dual interlocking plunger mechanism, it provides over 3,000 lbs of tested static strength, 350 ft-lbs of dynamic strength, and 1 million operating cycles. The non-handed strike supports 12/24 VDC operation, fail-secure or fail-safe configurations, and interchangeable faceplates for metal and wood door frames.
HES 1006 Series Electric Strike - Grade 1 Heavy-Duty Universal Access Control
The HES 1006 Series electric strike provides electronically controlled door release for commercial and institutional openings equipped with compatible cylindrical or mortise locksets, including models with or without a deadbolt. Designed around a universal strike body and interchangeable faceplate system, the 1006 Series accommodates locksets designed for a standard 4-7/8-inch ANSI strike preparation. Its dual interlocking plunger design permits controlled latch release through an access control panel, card reader, keypad, or intercom system while retaining compatible mechanical locking hardware. This flexibility makes the 1006 suitable for new construction, security upgrades, and retrofit installations where maintaining the existing lockset is preferred.
Engineered for demanding commercial applications, the HES 1006 features heavy-duty stainless steel construction, a tamper-resistant design, and a strike mechanism tested to exceed 3,000 lbs of static strength and 350 ft-lbs of dynamic impact resistance. The strike has been tested for more than 1,000,000 operating cycles and meets ANSI/BHMA A156.31 Grade 1 requirements. Its dual-voltage solenoid operates on 12 or 24 VDC continuous-duty power, with fail-secure operation standard and fail-safe configurations available. The series is also UL 1034 burglary-resistant listed, UL 294 listed, and suitable for outdoor applications. Qualifying fail-secure installations carry UL 10C fire ratings of up to 3 hours for single-door assemblies and 1-1/2 hours for double-door assemblies.
The 1006 Series interchangeable faceplate system accommodates cylindrical latchbolts, mortise latchbolts, and compatible mortise locks incorporating deadbolts up to 1 inch (25.4 mm) in projection. Faceplate selection determines compatibility with the lock manufacturer, latch geometry, and required deadbolt operation, including night-latch, deadbolt lockout, and deadbolt recapture applications. Customers can purchase the electric strike body with a separately selected faceplate or choose a Complete Pac configuration. Available packages include the CLB kit for latchbolt applications, CDB and CAS kits for compatible deadbolt applications, and the CS kit, which includes multiple faceplates and the SMART Pac III power controller. Optional LBM latchbolt monitoring and LBSM latchbolt strike monitoring provide additional feedback for compatible access control systems.
Designed for installation in metal or wood door frames, the non-handed HES 1006 supports both left-hand and right-hand door applications. Its 1-11/16-inch (43 mm) strike body depth, removable plug-in electrical connectors, and supplied keeper shims simplify installation and latch alignment when used with the appropriate frame preparation. Available architectural finishes include satin stainless steel (630), bright stainless steel (629), bright brass (605), satin brass (606), satin bronze (612), dark bronze (613E), and black (BLK). The series is backed by the manufacturer's five-year SecuriCare no-fault warranty, which extends to 10 years when installed with the SMART Pac III. For proper operation, installers must verify the selected faceplate, lockset compatibility, electrical requirements, and applicable fire-rating conditions before installation.
Features
- Works with virtually every cylindrical or mortise lockset, including those with a 1" deadbolt.
- Stainless steel body with dual interlocking plunger design, tested to 3,000 lbs static load and 350 ft-lbs impact.
- Exceeds ANSI/BHMA A156.31 Grade 1; cycle tested beyond 1,000,000 operations.
- Field selectable fail-secure (standard, locked on power loss) or fail-safe (unlocked on power loss).
- Dual voltage 12 or 24 VDC continuous duty with low current draw (450 mA @ 12 V, 250 mA @ 24 V).
- Non-handed for left or right hand doors; keeper shims shipped with the body for on-site alignment.
- Interchangeable faceplate system covers a range of lock brands, latch shapes, backsets, and deadbolt combinations.
- Optional LBM latchbolt monitor and LBSM latchbolt strike monitor outputs for door status reporting.
- UL 10C fire rated 3 hours single door / 1-1/2 hours double door (fail-secure); UL 1034 outdoor rated; windstorm certified.
- Plug-in connector for quick wiring; fits standard 4-7/8" ANSI preps in metal or wood frames.
- 5 year no-fault warranty, extended to 10 years with the SMART Pac III power controller.
Specifications
General
- Function
- Heavy-duty universal electric strike, ANSI/BHMA A156.31 Grade 1
- Lock Compatibility
- Cylindrical and mortise locksets, including locks with a 1" deadbolt
- Material
- Stainless steel, dual interlocking plunger design
- Body Dimensions
- 4-7/8" x 1-3/4" x 1-11/16" deep; fits standard ANSI strike cutout
- Frame Types
- Metal or wood door frames, mounting hardware for both included
- Handing
- Non-handed; keeper shims shipped with the body for horizontal adjustment
- Operating Mode
- Fail-secure standard; field convertible to fail-safe
- Holding Strength
- 3,000+ lbs static; 350 ft-lbs dynamic impact
- Cycle Endurance
- 1,000,000+ tested cycles
- Faceplates
- Interchangeable; Complete Pac kits bundle common styles, additional plates sold separately
- Warranty
- 5 year no-fault; 10 years total when installed with SMART Pac III
- Ordering
- Base strike by finish, monitoring, and fail mode; optional Complete Pac kit
Electrical
- Voltage
- Dual voltage 12 or 24 VDC, continuous duty
- Current Draw
- 450 mA @ 12 VDC; 250 mA @ 24 VDC
- Monitoring Outputs
- Optional LBM latchbolt monitor and LBSM latchbolt strike monitor, Form C dry contacts
Complete Pac Kits
- CLB
- Latchbolt applications; includes J, K, KD, and KM faceplates
- CDB
- Deadbolt applications; includes HM and AD faceplates
- CAS
- Includes N, ND, and NM faceplates
- CS
- Includes SMART Pac III power controller plus J, KD, KM, HM, and ND faceplates
Finishes
- 630
- Satin Stainless Steel (standard)
- 629
- Bright Stainless Steel
- 605
- Bright Brass
- 606
- Satin Brass
- 612
- Satin Bronze
- 613E
- Oil Rubbed Bronze
- BLK
- Black
Certifications and Compliance
- ANSI/BHMA A156.31
- Grade 1
- UL 1034
- Burglary-resistant listed, rated for outdoor use
- UL 294
- Access control system units
- UL 10C
- Fire rated 3 hours single doors, 1-1/2 hours double doors (fail-secure mode)
- CAN/ULC-S104 / NFPA 252 / ASTM E152
- U.S. and Canadian fire door test standards
- ANSI/SDI A250.13 / ASTM E330
- Windstorm and hurricane resistance standards
- Florida Building Code
- TAS 201/202/203 approved for hurricane impact rated openings
- RoHS
- Compliant
Frequently Asked Questions
- Does the 1006 work with deadbolts?
- Yes - unlike most electric strikes, the 1006 accommodates cylindrical and mortise locksets including a 1" deadbolt, with deadbolt faceplate kits such as the CDB Complete Pac.
- How is it different from the HES 1500 and 1600?
- The 1500/1600 add in-frame adjustability but hold 1,500 lbs and do not capture a full 1" deadbolt. The 1006 delivers 3,000+ lbs holding force and covers latch and deadbolt applications in one body.
- Is it fail-safe or fail-secure?
- Fail-secure is standard (locked on power loss); it is field convertible to fail-safe, or can be ordered either way.
- What power does it require?
- 12 or 24 VDC continuous duty, drawing 450 mA @ 12 V or 250 mA @ 24 V.
- Can it report door status?
- Yes - optional LBM (latchbolt monitor) and LBSM (latchbolt strike monitor) switches provide Form C dry contact outputs to access control systems.
- Can it be installed outdoors?
- Yes - it is UL 1034 listed and rated for outdoor use.
- Is it fire rated?
- Yes - UL 10C fire rated for 3 hours on single doors and 1-1/2 hours on double doors in fail-secure mode.
- What warranty does it carry?
- A 5 year no-fault warranty, extended to 10 years total when installed with the SMART Pac III power controller (included in the CS kit).
For more information about the Hanchett Entry Systems (HES) 1006-BASE, please contact us.