Potter Amseco PAV Air Vent


  • Also known as: PL-PAV

  • The PAV is an automatic float type air vent used to reduce the amount of air trapped in a pressurized fire sprinkler system. Reducing the amount of air in a fire sprinkler system is essential to help protect the system piping from the effects of corrosion that is often found at the air/water interface in the fire sprinkler system piping.

    Removing as much air as possible will also have a positive effect on the performance of vane type waterflow detectors. The operation of vane type waterflow detectors can be delayed or prevented if too much air is trapped in the system piping.

    The intent of the product is to vent as much air from the fire sprinkler system as possible. The PAV provides automatic venting of air as the system is being filled. Furthermore, trapped air can also be vented as the air in the system migrates to the vent location over time. The air vent will automatically close when water reaches the vent. The PAV provides a 1/2" NPT-male connection which will allow installers to safely pipe to a drain, any inadvertent discharge of water that is inherent in the operation of the automatic air vent.


    Technical Specifications:

    • Service Pressure: Up to 175 PSIG
    • Temperature Range: 40F to 120F (4.5C to 49C)
    • Air Vent: 1/2" NPT inlet/ 1/2" MNPT outlet to drain
    • 5/64" Orifice
    • Brass construction


    UPC: 999999400329

    For more information about the Potter / Amseco PAV, please contact us.

    Average Customer Review: Average Customer Review: 5 of 5 5 of 5 Total Reviews: 2 Write a review.

      9 of 9 people found the following review helpful:
     
    5 of 5 Review left on 5/24/2013 September 29, 2022
    Reviewer: Modesta Watkins from Linden, WI  
    Purchased the Potter / Amseco PAV

    Was this review helpful to you?

      4 of 4 people found the following review helpful:
     
    5 of 5 Review left on 8/3/2013 September 29, 2022
    Reviewer: Corinne Bates from Three Springs, PA  
    Purchased the Potter / Amseco PAV

    Was this review helpful to you?


    Browse for more products in the same category as this item:

    Potter / Amseco > Fire Sprinkler Monitoring > Corrosion Monitoring
    Potter / Amseco
    Potter / Amseco > Fire Sprinkler Monitoring
    Potter / Amseco > Corrosion Solutions
    Potter / Amseco > Fire Sprinkler Monitoring > Vents, Valves, & Drains
    Potter / Amseco > Corrosion Solutions > Treatment