Home > Edwards Signaling > Fire Alarm Systems > Detection Devices > SD Series >

Edwards Signaling SD4WJ
SD4WJ Edwards Signaling | JMAC Supply
 
Limited Stock
Our Price: $263.00



Product Code: EDWARDS-SIGNALING-SD4WJ
Qty:

Description Product Resources
 

Edwards Signaling SD4WJ


  • Also known as: ED-SD4WJ

  • The EDWARDS-SIGNALING-SD4WJ is a 4-wire duct smoke detector with photoeletric type that features environmental compensation with differential sensing, which enables the unit to be immune from sensitivity drift a common cause of false alarms.

    Every eight minutes the SD4WJ checks its environment for dirt, humidity other conditions that normally interfere with sensor operation, and automatically adjusts its sensitivity to compensate. The unit can be tested for dirt contamination remotely, eliminating the need to physically access the detector with a sensitivity tester.

    The SD4WJ's snap-in RJ45 connectors reduce time spent on controller/detector interconnection to just a few seconds, while sampling tube spacing - and even field wiring connections - match standard configurations.
    Features:
    • Less than 2" deep for easy installation and applications where space is tight
    • PCB mounted photoelectric sensor with on-board inteliigence
    • Environmental compensation with patented differential sensing
    • Standard RJ45 interconnection
    • Status LEDs remain visible even after installation
    • Cover tamper reed switch
    • Sampling tubes install from room-side or air-side
    • Magnet-activated test/dirty switch


    Technical Specifications:

    • Controller Dimensions: 6.75 x 5.45 x 1.90 inches (17.15 cm x 13.84 cm x 4.83 cm)
    • Sensor Dimensions: 8.70 x 5.45 x 1.90 (22.10 cm x 13.84 cm x 4.83 cm)
    • Controller with Sensor Dimensions: 14.51 x 5.45 x 1.90 (36.86 cm x 13.84 cm x 4.83 cm)
    • Wire Size: High voltage power input terminals (L&N): #12 to #22 AWG All others: #14 to #22 AWG
    • Smoke Detection Method: Photoelectric
    • Air Velocity Rating: 100 to 4,000 ft/min and meets the required minimum air pressure differential
    • Air Pressure Differential: 0.005 to 1.00 inches of water
    • Sensitivity: 0.67 to 2.46 %obscuration/ft
    • Reset Time: 2 seconds, max.
    • Power Up Time: 8 seconds, max.
    • Alarm Test Response Time: 5 to 7 seconds
    • Alarm Initiation Relay: Quantity - 1 Style - Normally Open Ratings: 2.0 A at 30 VDC (resistive)
    • Auxiliary Output: 18 VDC, nom., 30 mA, max.
    • Operating Voltages: 24 VDC, 24 V at 50/60 Hz, 120 V at 50/60 Hz, 220/240 V at 50/60 Hz


    UPC: 0793016035776

    Average rating: 5.0, based on 2 reviews


    For more information about the Edwards Signaling SD4WJ, please contact us.

    Share your knowledge of this product with other customers... Be the first to write a review

    Browse for more products in the same category as this item:

    Edwards Signaling > Fire Alarm Systems > Detection Devices > SD Series
    Edwards Signaling
    Edwards Signaling > Fire Alarm Systems
    Edwards Signaling > Fire Alarm Systems > Detection Devices
    Burglar Alarms > Smoke Detectors > Addressable Smoke Detectors
    Burglar Alarms > Smoke Detectors